Date
Input-coded set selection
ID
IB
I4
I2
I1
Set
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
2
0
2
0
0
3
0
0
3
0
4
0
0
0
4
5
0
0
0
0
5
5
0
3
0
0
3
5
0
3
0
1
1
Picture 6.8.3.c
Input-coded parameter set selection
At input-coded set selection
-
maximal 7 of the internal or external inputs may be programmed for set selection
(0…7 sets) within one parameter set to avoid set selection errors.
-
the lowest of the selected inputs has priority
(I1 > I2 > I3 > I4 > IA > IB > IC > ID)
Eample1:
With 5 inputs (I1, I2, I4, IB and ID) set 0…5 shall be selected
1.)
Adjust parameter di.3, di.4, di.6, di.8 and di.10 to value „1“
2.)
Parameter di.5, di.7 and di.9 must be set to
≠
1
3.)
Adjust Fr.2 to vlaue „3“ (set selection input-coded via terminal strip)
Set 0
Set 1
Set 2
Set 3
Set 4
Set 5
I1
I2
I4
IB
ID
6.8.4
Locking of Para-
meter Sets
Parameter sets that shall not or may not be selected can be locked with Fr.3. If the
locked set is selected, the inverter switches off with set selection error (E.SEt).
Value
Locked set
Example
1
0
-
2
1
-
4
2
4
8
3
-
16
4
-
32
5
32
64
6
-
128
7
-
Set 2 and set 5 locked
Sum 36
Fr.3 Parameter set lock