3.2 Technical data of the axis modules
Module mode
Single axis
Double axis
Device size
07
10
12
07
10
12
Housing
b P b P b P b P b P b P
Rated output power
S
out
/ kVA
1.8
4
6.2
2.18
2 x 4 2 x 6.2
Max. rated motor power
P
mot
/ kW 0.75
2.2
4
2 x 0.75 2 x 2.2 2 x 4
Rated output current
I
out
/ A
2.6
5.8
9
2 x 2.6 2 x 5.8 2 x 9
Short time current limit at 0 Hz
I
f0
/ A
5.2
9
9
2 x 5.2 2 x 9
2 x 9
Short time current limit
1)
I
_max
/ A
5.2
11.6
18
2 x 5.2 2 x 11.6 2 x 18
Min. frequency at short time current limit
f
d
/ Hz
1
1
5
1
1
5
Output voltage
U
out_ac
/ V
3-phase 0…
U
in
/ √2
Output frequency
f
out
/ Hz
recommended upto 1/10 of the switching frequency
Switching frequency
f
S
/ kHz
4
Power dissipation heat sink
P
VK
/ W
18
37
58
36
74
116
Power dissipation interior
P
VI
/ W
18
22
26
26
34
42
Max. heat sink temperature
T
HS
/ °C
80
Motor cable cross-section
Ø
/ mm²
1.5
1.5
2.5
2 x 1.5 2 x 1.5 2 x 2.5
Max. motor cable length shielded
l
/ m
35
Supply power unit
Rated input voltage
U
N_dc
/ V
565
Input voltage range
U
in_dc
/ V
452...840
Supply control unit
Rated input voltage
U
N_dc
/ V
24
Input current
2)
I
in_dc
/ A
1
Additional input current for air cooler
I
_dc
/ A
0.15
Table 7:
Overview of the device data housing B, P
1)
The overcurrent cut-off (E.OC) occurs approx. 20% over the short time current limit.
2)
Without external load by digital outputs, encoder, brake or fan.
Long-time overload (E.OL)
Short-time overload (E.OL2)
t
in s
I/I
N
in %
t
=60s
E.OL
100%
150%
f
d
f
0
f
out
in Hz
I
N
in %
I
N
I
OC
I
f0
I
_max
E.OL2
Figure 1:
Overload characteristic (E.OL, E.OL2)
28
TEcHNIcAL DATA Of THE AXIS MODULES