DEvIcE DATA cOMbISTOP 38
3.2 Device data cOMbISTOP 38
3.2.1 Overview
Device size
02
03
04
05
06
07
08
09 10
11
Rated torque after
running-in at 20 °C
N version
1)
M
2N
/ Nm
5
10
20
36
70
100
150
250
500 1000
Rated torque after
running-in at 20 °C
H version
1)
M
2N
/ Nm
7.5
15
30
50
90
150
225
375
750 1500
Rated power N version
P
20
/ W
25
30
30
48
62
65
75
80
130
180
Rated power H version
P
20
/ W
25
30
30
48
75
90
90
115
180
280
Rated voltage
2)
U
N_dc
/ V
24 / 105 / 180 / 205
3)
Cyclic duration factor
ED
/ %
100
Speed for service
braking
n
/ rpm
3000
1500
Max. speed for
emergency braking
n
_max
/ rpm
6000
5000
4500 3500
3000
2000
Mass moment of inertia
J
/ 10
-3
kgm² 0.025 0.075 0.227 0.553 0.771 1.84 6.17 17.22 45.28 153.6
Nominal air gap
X
/ mm
0.2
0.3
0.4
0.5
0.6
Switching cycles for
half-wave rectifier
4)
SC1
/ rpm
60
25
5
2
1
Switching cycles for
bridge rectifier
4)
SC2
/ rpm
120
75
75
50
10
5
3
2
Switching cycles with
power box DC
SC3
/ rpm
55
40
40
25
5
2
1
─
Separation time
5)
t
2
/ ms
40
55
90
110
240
220
320
350
400
750
Separation time with
power box
5)
t
2
/ ms
20
35
50
60
120
120
150
170
180
─
Response delay AC
6)
t
11_ac
/ ms
70
100
180
220
260
400
700
900 1400 3100
Response delay DC
6)
t
11_dc
/ ms
10
15
25
25
25
40
50
60
100
450
Engagig time AC
7)
t
1_ac
/ ms
100
150
200
240
330
650
900 1200 2000 3500
Engaging time DC
7)
t
1_dc
/ ms
20
30
50
55
90
120
180
220
300 1000
Feather key
according to
Keyway
ISO class
B (optional F and H)
Table 5:
Device data COMBISTOP Type 38
1)
The torques are based on a quasi-static measurement with a differential speed of 25
rpm
.
2)
Special voltage upon request.
3)
105 V / 180 V / 205 V fall under the Low-Voltage Directive =>
„11.1 EU declaration of conformity“
4)
Maximum permissible switching cycles for DC-switching, continuous operation (100 % ED) and max.
operating temperature of 80 °C.
5)
Separation time from switching on the current to the beginning of the torque drop. The values are to be
regarded as guidelines.
6)
Time from switching off the current until increase in torque. The values are to be regarded as guidelines.
7)
Time from switching off the current until reaching 0.9 x rated torque M
2N
. The values are to be regarded as
guidelines.