4.3.2.4 Mount the Magnet
1. Orient the magnet such that the lead wire exits in the desired position.
2. Slide the magnet (9) onto the M10 mounting studs (8).
Figure 10 Magnet Installation
3. Slide the washers (10) onto the M10 mounting studs (8) and fasten a nylon lock-nut (11)
to each stud.
4. Tighten the lock-nuts equally in stages to compress the pressure springs and reduce the
air gap between the magnet and armature.
Proceed to Checking the Air Gap