heating
through
innovation.
iVECTOR (TYPES BC, BN, FC, FN)
INSTALLATION & OPERATING MANUAL
Please leave this manual with the end user
Part Number: P25M1387
Product Serial Number
:
Страница 1: ...heatingthroughinnovation iVECTOR TYPES BC BN FC FN INSTALLATION OPERATING MANUAL Please leave this manual with the end user Part Number P25M1387 Product Serial Number...
Страница 2: ...and user maintenance shall not be made by children unless they are older than 8 years and supervised Keep the appliance and its cord out of reach of children aged less than 8 years Children of less th...
Страница 3: ...n the disposal of the condensate must be considered For types BC and BN follow stages a f from FIG 5 and for types FC and FN follow stages a c then g i to show how to fit product to the wall Note Do n...
Страница 4: ...Parameters Refer to table on page 6 Select Clock Set Time Select Comfort Setting Set room temperature to desired setting default 21 C Fan runs in heating cooling Press hold for 5 secs to change betwee...
Страница 5: ...g to one of the 9 preset timed programs or one of the 4 user defined programs See page 6 for program options and setup Press OK to view the actual set temperature Comfort or Set back Night Set back Se...
Страница 6: ...ressing ok to confirm Cooling set point CSP The default water switching temperature for cooling is 15 C this can be altered by pressing or keys then pressing ok to confirm Calibration of the internal...
Страница 7: ...ing too high cooling Minimum 32 C Heating Maximum 15 C Cooling Lack of water flow Unit incorrectly sized against heat loss Problem Remedy Switch on supply Replace fuse Switch unit on at LCD display Re...
Страница 8: ...308 382 480 526 154 3 596 141 4P 125 2P 29 69 99 95 111 105 iVECTOR Appendix 32 2P 4P 4P Fig 4 1 2 3 5 4 8 Tools required Fig 1 Fig 2 Fig 3 6 7 4 pipe only Type FN FC only Dimensions mm...
Страница 9: ...33 iVECTOR Appendix continued A 297 A 297 239 89 457 5d 5e 5f 5g 5h 5i 5a 5b 5c A 800 1000 1200 1400 1600 APPENDICES Type FN FC only Type BN BC only Fig 5 Abb 5 Rys 5...
Страница 10: ...34 iVECTOR Appendix continued 8a 8b Fig 6 BN FN BC FC Fig 7 8c Fig 8 Power Board Cable Entry Points Terminal Block Motor Control Board Power Supply EC Adaptor...
Страница 11: ...35 iVECTOR Appendix continued APPENDICES 8g 8f 8h 8i A B C D 1 5 m 1 2 m 8d A A Type BC FC only Fig 9 SECTION A A Wire route channel Possible wire route 8e...
Страница 12: ...36 iVECTOR Appendix continued 1 Type BC FC only Fig 10a...
Страница 13: ...37 iVECTOR Appendix continued 2 Type BN FN only Fig 10b APPENDICES 1 2 GND GND 0 10V Out N L M 1 2 3 4 5 6 7 8 9 10 V V L N bk r r bk w w bk bl br bk r w 0 10V In 0 10V DC Output 4 3 11 12 D...
Страница 14: ...Output VH Live out 10 0 24 0 L w w w bk 0 10V In bk VC Live out VH Neutral out N VC Neutral out 2 5 6 3 4 1 Type BC FC 8 9 V V N bl br bk r 1 L L GND 0 10V Out 2 GND 0 10V In bl br N L 4 3 EC Adapter...
Страница 15: ...age Free Relays 10 0 24 0 L w w w bk 0 10V In bk VC Live out VH Neutral out N VC Neutral out GND GND 0 10V Out M 1 2 3 4 5 6 7 8 9 10 V V L N bk bk bk r r r r bk w w bk bl br bl br bk r 0 10V DC Outpu...
Страница 16: ...40 iVECTOR Appendix continued Fig 10e 2p Type BC FC 2p Type BC FC and Type BN FN 5 5 5 5 4p Type BC FC 4p Type BC FC and Type BN FN...
Страница 17: ...k Power Board Control Board Air Sensor Water Sensor Water Sensor 4P Only Voltage Free Terminals Valve Switching Output to Slave unit Optional Air Sensor Terminal Block Input from Master unit Optional...
Страница 18: ...1729 1288 4147 3088 Performance Data 4 Pipe Type BC BN FC FN Relative Humidity Sensible cooling at 50 Model Flow l h T20 T25 T30 T35 T40 T45 T50 Heat Output Watts Cooling Watts Condition 7 12 27 Fan S...
Страница 19: ...11 12 2 14 2 12 2 17 22 2 24 4 28 4 26 35 6 45 8 49 8 57 4 Sound levels tested in accordance with ISO 3741 Sound performance show at fan speeds via controls unit may differ with external controller 2...
Страница 20: ...01 05 2017 ISSUE 1 heatingthroughinnovation...