- 10 -
Ring Installation
●
Tilt the lever to your right to unlock the casting
Set a casting ring against the melting alloy
ring stand. Insert the provided tweezers to the
outlet without gap between melting alloy and
hole of the lever and move up and down in
casting ring
Note) When taking hot casting rings out, use a heat
accordance with size of casting ring.
resistant glove and tongs to prevent skin burn.
There are labels of 3, 4, 6, 8, 9 on the backside of the casting ring stand.
Nearly Equal; 3: dia.34
4: dia.46
6: dia.60
8: dia.80
9: dia.90
、
、
、
、
Note) Do not touch the casting ring stand. This may cause skin burn.
Chamber Lid Locking
●
Place a casting ring and close the chamber lid.
Note) Open and close the chamber lid gently to prevent malfunction.
Move up and put the lever on the ditch.
Move down the lever to turn on the lock switch
and ready to cast.