Table 5 :
NO.
PROBLEM
CAUSE
CORRECTIVE ACTION
1.
Thermostat does not function
Thermostat damaged
Check and replace. Check
Thermostat when adjusting
temperature, Pin 1 and 2 must
connected.
2.
Thermostat with ON / OFF switch
does not function
ON / OFF switch damaged
Check and replace. Check
Thermostat when turned ON,
Pin 5 and P5 must be
connected. Pin 6 and P6 must
be connected.
3.
Pilot lamp does not function
Pilot lamp damaged
Check and replace
No electric current between
Thermostat and Pilot lamp
Check and repair
4.
Heating element does not
function
Heating element damaged
Check and replace
No electric current between heating
element, Thermostat, and Pilot lamp
Check and repair
5.
Griddle’s temp
erature cannot
raise / heat up
Heating element damaged
Check and replace
No electric current between heating
element, Thermostat, and Pilot lamp
Check and repair
6.
Griddle leaves Black Particle
Cleaning not done properly
Repair re-season if possible
otherwise replace griddle
Griddle are unused for a long time
and exposed to oxidation
7. Trouble Shooting