Страница 3: ...ßen 11 Liege anschließen 12 Decke und Rückwand anschließen 14 General information 19 About these instructions 19 Definitions 19 Application note 19 Safety notes 19 Intended use 19 Preliminary information 20 Replacing defective ballasts 21 Ballast replacement example 22 Overview DSI DALI converter 24 Connecting the converter 25 Connecting the power supply 25 Connecting the bed bench 26 Connecting t...

Страница 4: ...als auch im Ganzen ist zu unterlassen AUSSCHLUSSERKLÄRUNG Alle Angaben in diesem Dokument entsprechen dem aktuellen Stand zum Zeitpunkt der Indrucklegung Sie erfolgen jedoch ohne Gewähr unter Vorbehalt eventueller Änderungen und unter Ausschluss jeglicher Haftung Aktuelle Anleitungen finden Sie unter https media kbl de KBL GmbH Ringstraße 24 26 56307 Dernbach Germany fon 49 0 2689 9426 0 fax 49 0 ...

Страница 5: ...n an KBL Besonnungsgeräten geschult und autorisiert wurde Verwendungshinweis Für die Verwendung des DSI Dali Kon verters werden Dali Ersatzteil EVG s 5119900039 benötigt Vor allen Arbeiten ist das Besonnungsgerät von der Netzspannung zu trennen GEFAHR Spannungsführende Bauteile Lebensgefahr durch Stromschlag bei Kontakt mit spannungsführenden Bau teilen Freischalten Gegen Wiedereinschalten sichern...

Страница 6: ... für den Tausch der EVG s in der Liege ist am geringsten Daher ist es zu Empfehlen den Konverter z B an Kanal Liege 2 anzuklemmen dort alle alten EVG s gegen neue Dali EVG s zu tauschen und die funktions fähigen alten EVG s für den Austausch der defekten alten EVG s an den übrigen Kanälen zu verwenden BEISPIELHAFTE GERÄTEGRUPPE Diese Anleitung beschreibt den Anschluss des DSI DALI Konverters beisp...

Страница 7: ...9 1 47 49 20 2 28 30 21 2 32 34 22 2 36 38 23 2 40 42 24 2 44 46 25 2 48 50 Nachstehende Darstellungen zeigt die EVG Kanal Röhren Zuordnung basieren auf dem Schaltplan der Beispielgruppe 6808 7908 UV Geräte ohne P2 Röhren Die EVG Röhren Zuordnung kann von diesem Beispiel abweichen Identifizieren Sie defekte EVG s immer anhand des Schaltplanes Ihres Gerätes DECKE Röhre 1 Röhre 20 EVG 1 2 3 4 5 6 7 ...

Страница 8: ...VG s an Kanal 2 Liege gegen DALI EVG s zu tauschen Anschließend kann ein funktionsfähiges DSI EVG aus Kanal 2 für den Austausch des defekten DSI EVG 13 Kanal 4 Rückwand verwendet werden Durch diese Vorgehensweise muss der DSI DALI Konverter nur an Kanal 2 ange schlossen werden Siehe Nachfolgende Kapitel zum Kon verteranschluss DSI EVG S AUSBAUEN KANAL 2 20 21 22 23 24 25 IO defekt Entsorgen Als Er...

Страница 9: ...r e i n b a u e n 9 DSI EVG 13 AUSBAUEN KANAL 4 13 defekt Entsorgen A u s b a u e n DSI EVG 13 EINBAUEN KANAL 4 Ein funktionsfähiges DSI EVG aus der Liege Kanal 2 für den Austausch verwenden 1x Funktionsfähiges DSI EVG aus Kanal 2 E i n b a u e n ...

Страница 10: ...3a D3B D3C DSI DALI DSI DALI Konverter 3220323770 LINE X5 XST2 X5a XST2a Anschluss für die Liege Werkseitige Standardbelegung Anschluss für Decke und Rückwand Werkseitige Standardbelegung Spannungsversorgung Übersicht DSI DALI Konverter Artikelnummern Konverter Box 3220323770 Kabelbaum 3210985075 Wird komplettiert geliefert ...

Страница 11: ...räte haben unter schiedliche Bezeichnungen für die Steckverbindungen 1 Geräteanschuss X5 X5a oder XST2 XST2a lösen 2 Y Stück des DSI DALI Konverters dazwischen klemmen X5 XST2 X5a XST2a ALTE ANSCHLUSSANORDNUNG NEUE ANSCHLUSSANORDNUNG X5 X5a XST2 XST2a X5 XST2 X5a XST2a Spannungsversorgung Konverter anschließen ...

Страница 12: ...n anzuschließen nur in Verbindung mit Kanal 2 Um Kanal 1 zusätzlich zu ver wenden verbinden Sie D1B D1 und D1C D1a LIEGE 1 2 1 2 1 2 1 2 1 2 1 2 XL2 XST6 XL2a XST6a Anschluss für die Liege Kanal 1 2 D1a D1C D1 D1B LIEGE 1 2 1 2 1 2 1 2 1 2 1 2 XL2 XST6 XL2a XST6a D1 D1a D1B D1C Anschluss für die Liege Kanal 2 Standard LIEGE 2 2 2 2 2 2 VARIANTE KANAL 1 2 VARIANTE KANAL 2 ÜBERSICHT ANSCHLUSSVARIANT...

Страница 13: ...eräte haben unter schiedliche Bezeichnungen für die Steckverbindungen 1 Geräteanschuss XL2 XL2a oder XST6 XST6a lösen 2 Y Stück des DSI DALI Konverters dazwischen klemmen XL2 XST6 XL2a XST6a ALTE ANSCHLUSSANORDNUNG NEUE ANSCHLUSSANORDNUNG XL2 XL2a XST6 XST6a ANSCHLUSS HERSTELLEN ...

Страница 14: ... Rückwand Kanal 4 Standard DECKE 3 3 3 3 4 4 4 4 4 3 RÜCKWAND 4 3 3 VARIANTE KANAL 4 VARIANTE KANAL 3 4 Der Kabelbaum ist werksei tig so konfektioniert dass nur Kanal 4 angeschlossen ist Es ist nicht möglich Kanal 3 einzeln anzuschließen nur in Verbindung mit Kanal 4 Um Kanal 3 zusätzlich zu ver wenden verbinden Sie D3B D3 und D3C D3a DECKE 4 4 4 4 4 RÜCKWAND 4 DECKE 3 3 3 3 4 4 4 4 4 3 RÜCKWAND 4...

Страница 15: ...eräte haben unter schiedliche Bezeichnungen für die Steckverbindungen 1 Geräteanschuss XD2 XD2a oder XST7 XST7a lösen 2 Y Stück des DSI DALI Konverters dazwischen klemmen XD2 XST7 XD2a XST7a ALTE ANSCHLUSSANORDNUNG NEUE ANSCHLUSSANORDNUNG XD2 XD2a XST7 XST7a ANSCHLUSS HERSTELLEN ...

Страница 16: ...S I 0 0 0 8 8 D S I D a l i C o n v e r t e r e i n b a u e n 16 Bemerkungen ...

Страница 17: ...S I 0 0 0 8 8 D S I D a l i C o n v e r t e r e i n b a u e n 17 Bemerkungen ...

Страница 18: ...ER All information given in this document correspond to the status quo at the date of publication but may be subject to changes Therefore we do not accept any liability for nor do we guarantee the accuracy and or completeness of the information For instruction updates please refer to https media kbl de KBL GmbH Ringstraße 24 26 56307 Dernbach Germany fon 49 0 2689 9426 0 fax 49 0 2689 9426 66 eMai...

Страница 19: ... the manufacturer for the installation and maintenance of KBL tanning devices Application note DALI replacement electronic ballasts 5119900039 are required for the use of the DSI DALI converter Before carrying out any work the tanning device must be disconnected from the mains voltage DANGER Live parts Risk of death or fatal injury due to electric shock when touching live parts Switch neutral Secu...

Страница 20: ...n the bed bench takes the least amount of work It is therefore recommended to connect the converter to the channel Bed Bench 2 for example replace all of the old electronic ballasts on this channel with new DALI electronic ballasts and use the working old electronic ballasts to replace defective old electronic ballasts on the other channels EQUIPMENT GROUP EXAMPLE These instructions describe the c...

Страница 21: ...49 20 2 28 30 21 2 32 34 22 2 36 38 23 2 40 42 24 2 44 46 25 2 48 50 The illustrations below show the ballast channel tube assignment based on the circuit diagram for the equipment group example 6808 7908 UV equipment without P2 tubes The ballast tube assignment may devi ate from this example Always identify defective ballasts according to the circuit diagram for your tanning device TOP Tube 1 Tub...

Страница 22: ...is recommended to replace all DSI ballasts on channel 2 bed bench with DALI ballasts Then a working DSI ballast from channel 2 can be used to replace the defective DSI ballast 13 chan nel 4 back wall With this approach the DSI DALI con verter only has to be connected to chan nel 2 See the following section for con necting the converter REMOVE DSI BALLASTS CHANNEL 2 20 21 22 23 24 25 OK Defective D...

Страница 23: ... o n v e r t e r 23 REMOVE DSI BALLAST 13 CHANNEL 4 13 Defective Discard R e m o v e INSTALL DSI BALLAST 13 CHANNEL 4 Use a working DSI ballast from the bed bench chan nel 2 as the replacement 1x Working DSI ballast from channel 2 I n s t a l l ...

Страница 24: ...3 D3a D3B D3C DSI DALI DSI DALI converter 3220323770 LINE X5 XST2 X5a XST2a Connection for the bed bench Factory standard assignment Connection for canopy and back wall Factory standard assignment Power supply Overview DSI DALI converter Item numbers Converter box 3220323770 Cable harness 3210985075 assembled delivered ...

Страница 25: ...plug con nectors of old and new tanning devices are different 1 Disconnect X5 X5a or XST2 XST2a equipment connection 2 Connect Y piece of DSI DALI converter in between X5 XST2 X5a XST2a OLD CONNECTION CONFIGURATION NEW CONNECTION CONFIGURATION X5 X5a XST2 XST2a X5 XST2 X5a XST2a Power supply Connecting the converter ...

Страница 26: ...y but only in con junction with channel 2 To use channel 1 in addition connect D1B D1 and D1C D1a BED BENCH 1 2 1 2 1 2 1 2 1 2 1 2 XL2 XST6 XL2a XST6a Connection for the bed bench Channels 1 2 D1a D1C D1 D1B BED BENCH 1 2 1 2 1 2 1 2 1 2 1 2 XL2 XST6 XL2a XST6a D1 D1a D1B D1C Connection for the bed bench Channel 2 standard BED BENCH 2 2 2 2 2 2 VERSION CHANNELS 1 2 VERSION CHANNEL 2 OVERVIEW CONN...

Страница 27: ...g con nectors of old and new tanning devices are different 1 Disconnect XL2 XL2a or XST6 XST6a equipment connection 2 Connect Y piece of DSI DALI converter in between XL2 XST6 XL2a XST6a OLD CONNECTION CONFIGURATION NEW CONNECTION CONFIGURATION XL2 XL2a XST6 XST6a ESTABLISHING THE CONNECTION ...

Страница 28: ... and back wall channel 4 standard CANOPY 3 3 3 3 4 4 4 4 4 3 BACK WALL 4 3 3 VERSION CHANNEL 4 VERSION CHANNELS 3 4 The wiring harness is assem bled at the factory so that only channel 4 is connected Channel 3 cannot be connec ted individually but only in con junction with channel 4 To use channel 3 in addition connect D3B D3 and D3C D3a CANOPY 4 4 4 4 4 BACK WALL 4 CANOPY 3 3 3 3 4 4 4 4 4 3 BACK...

Страница 29: ...g con nectors of old and new tanning devices are different 1 Disconnect XD2 XD2a or XST7 XST7a equipment connection 2 Connect Y piece of DSI DALI converter in between XD2 XST7 XD2a XST7a OLD CONNECTION CONFIGURATION NEW CONNECTION CONFIGURATION XD2 XD2a XST7 XST7a ESTABLISHING THE CONNECTION ...

Страница 30: ...ns 1 2 3 4 5 6 7 8 9 XD2 1 2 3 4 5 6 7 8 9 XL2 1 2 3 4 5 6 7 8 9 X5 1 2 3 4 5 6 7 8 9 XL2a 1 2 3 4 5 6 7 8 9 XD2a 1 2 3 4 5 6 7 8 9 X5a 1 2 D1a 1 2 D1 1 2 D1c 1 2 D1b 1 2 D3a 1 2 D3 1 2 D3c 1 2 D3b XSt7 XSt7a XSt6a XSt6 XSt2a XSt2 DALI output DSI input X3 X1 X2 A100 Dasi Dali Converter 5 1 6 2 7 3 8 4 5 1 6 2 7 3 8 4 1 5 9 10 Anlage Attachment ...

Страница 31: ......

Страница 32: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...