Thank you very much for purchasing our air conditioner.

Before using your air conditioner, please read this manual carefully and keep it for future 

reference.

INSTALLATION MANUAL

Console Unit 2

nd

 Generation 

KSDF-28 DN4.0

KSDF-36 DN4.0

KSDF-45 DN4.0

Содержание KSDF-28 DN4.0

Страница 1: ...ery much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference INSTALLATION MANUAL Console Unit 2nd Generation KSDF 28 DN4 0 KSDF 36 DN4 0 KSDF 45 DN4 0 ...

Страница 2: ......

Страница 3: ...o not come in direct contact with the refrigerant leaking from the connections of refrigerant piping Otherwise it may lead to frostbite The air conditioner must be grounded Do not connect the earth line ground to gas piping water piping lightning rods or telephone earth lines Improper grounding can lead to electric shock or fire and may cause mechanical failure due to current surges from lightning...

Страница 4: ... 6 where there is a risk of leakage of flammable gases Examples are sites that contain carbon fibres or combustible dust in the air or where there are volatile combustibles such as diluent or petrol The above gases may cause explosion and fire 7 Do not touch the fins of the heat exchanger as this may lead to injury 8 Some products use the PP packing belt Do not pull or tug on the PP packing belt w...

Страница 5: ...culated for the selected model in the installation manual of the outdoor unit and your actual project requirements To purchase based on actual project requirements Use to connect indoor refrigerant piping 2 PVC pipe for water discharge Inner diameter 18 mm To purchase based on actual project requirements Use to discharge condensed water from the indoor unit 3 Insulation casing for piping The inner...

Страница 6: ...ix the hook with tapping screw onto the walll which can support the weight of the indoor unit Refer to Figure 3 2 1 Open the front panel 2 Remove the 4 screws and remove the front grille while pulling it forward 3 tabs Take note of the following when transporting the equipment 1 Fragile Handle with care 2 Determine the route to move the unit to the installation site 3 Transport the equipment on th...

Страница 7: ...e to form water that may leak from the system 4 Insert the bundled piping and wiring from outside the room through the wall opening into the room Be careful when you lay out the piping Do not damage the piping Refer to the installation manual attached with the outdoor unit on installation of the refrigerant piping for the outdoor unit All gas and liquid piping must be properly insulated otherwise ...

Страница 8: ...he Indoor Unit Apply the appropriate tightening torque according to the installation conditions Excessive torque will damage the socket cap and the cap will not be tight if you apply insufficient torque leading to leakages For the vacuum make sure that the air and liquid cut off valves of the outdoor unit are all closed maintain the factory status The Air Tightness Test helps to ensure that the ai...

Страница 9: ...ot place anything in the water pan All the supplied parts materials and electrical works must comply with local regulations Use only copper wires Use a dedicated power supply for the air conditioners The power voltage must be in line with the rated voltage The electrical wiring works must be carried out by a professional technician and must comply with the labels stated in the circuit diagram Befo...

Страница 10: ... MFA Maximum Fuse A mps FLA Full Load Amps IFM Indoor Fan Motor 6 2 Electrical Wiring Specifications 6 3 Communication Wiring 6 3 1 Communication wiring between the indoor and outdoor units 6 3 2 Communication wiring between the indoor unit and wired controller Model 2 8 4 5kW Power supply Phase 1 phase Volt and frequency 220 240V 50Hz 220 240V 50 60Hz Communication wire between indoor and outdoor...

Страница 11: ...fer to the manual on the outdoor unit Once the wiring and connections are done use tie straps to secure the wiring properly so that the connection joint cannot be pulled apart by external force The connection wiring must be straight out so that the cover of the electrical box is level and can be closed tightly Use professional insulation and sealing materials to seal and protect the perforated wir...

Страница 12: ...n enabled Auto restart function disabled Caution All DIP switches including the capacity DIP switch have been configured before delivery Only a professional maintenance personnel should change these settings Improper DIP switch settings may cause condensation noise or unexpected system malfunction 7 4 Error Codes and Definitions Error code Content E0 Mode conflic t E1 Communication error between i...

Страница 13: ...s disconnected before any servicing or maintenance is carried out Do not touch the unit or its remote controller with wet hands as doing so can lead to electric shocks Do not allow children to play near this unit as doing so risks injury Do not insert your fingers or other objects into the unit s air inlet or air outlet to avoid injury or damage to the equipment Do not spray any liquids onto the u...

Страница 14: ...hey have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 9 Part Names 10 The Explain Of The Display Panel The figure shown above is for reference only and may be slightly different from the actual product ...

Страница 15: ...flow as doing so might ensure more efficient operation The operating temperature range under which the unit runs stably are given in below table Figure 11 1 Figure 11 2 Figure 11 3 Figure 11 4 Check regularly Close doors and windows Caution The unit performs stably in the temperature range given in above table If the indoor temperature is outside the unit s normal operating range it may stop runni...

Страница 16: ...r filter can prevent the dust or other particles from entering the unit If the filter is blocked the unit will not work well Clean the filter every two weeks when you use it regularly b If the air conditioner is positioned in a dusty place clean the filter often c Replace the filter if it is too dusty to clean the replaceable air filter is an optional fitting d When heating adjust the louver downw...

Страница 17: ...inutes under some operating conditions If the OPERATION LED on the unit s panel is lighting the system is working normally and the unit will start after the intentional delay is complete Heating mode is running when the following panel lights are on operation and the DEF FAN LED indicator Cause the indoor unit activates protective measures because of the low outlettemperature Symptom 2 The unit em...

Страница 18: ...efrigerant circuit The outdoor unit compressors have malfunctioned The power supply voltage is too high or too low There is a blockage in the piping system Low cooing effect Doors or windows are open Close the doors and windows Sunlight is shining directly onto the unit Close shutters blinds to shield the unit from direct sunlight The room contains many heat sources such as computers or refrigerat...

Страница 19: ...can be selected during COOL FAN ONLY and HEAT The remote controller signalis not transmitted even when the ON OFF button is pushed A power cut has occurred the power to the premises has been cut off Wait for the power to come back on The remote controller s batteries are running out Replace the batteries The indication on the display disappears after a certain time Check whether the timer operatio...

Страница 20: ...oor and outdoor units not connected properly Interference from high voltage wires or other sources of electromagnetic radiation Communication wire too long Damaged main PCB Indoor ambient temperature sensor T1 error E2 Temperature sensor not connected properly or has malfunctioned Damaged main PCB Indoor heat exchanger mid point temperature sensor T2 error E3 Indoor heat exchanger outlet temperatu...

Страница 21: ...MD17I 019BW 16126000002967 ...

Страница 22: ......

Страница 23: ......

Страница 24: ......