background image

 

 

 
 
 
 

OWNER’S MANUAL 

 
 

Compact Four-Way Cassette 

 
 
 
 
 

KCI-26DMR11 
KCI-35DR11 

KCI-52DMR11 
KCI-35DVN11 

KCI-52DVN10 

 
 
 
 
 
 
 

 

IMPORTANT NOTE:

 

Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this 
manual for future reference.

 

Содержание KCI-26DMR11

Страница 1: ...t Four Way Cassette KCI 26DMR11 KCI 35DR11 KCI 52DMR11 KCI 35DVN11 KCI 52DVN10 IMPORTANT NOTE Read this manual carefully before installingoroperating yournewair conditioningunit Makesuretosave this manualforfuturereference ...

Страница 2: ...oor unit outdoor unit For R 410 units For R32 units KCI 35 DVN11 KCI 35 DR11 KUE 35 DVN11 KCI 52 DVN10 KCI 52 DN10 KUE 52 DVN10 Indoor Units For R 410 units For R32 units KCI 26 DMR11 KCI 35 DR11 KCI 52 DMR11 ...

Страница 3: ...Table of Contents Owner s Manual SafetyPrecautions 04 Indoor Unit Parts and Major Functions 06 ManualOperations 08 ...

Страница 4: ... b How to Clean the Air Filter 09 c Repairing Refrigerant Leaks 10 d Preparation for Periodsof Non use 10 Troubleshooting 11 a CommonProblems 11 b Troubleshooting Tips 12 European Disposal Guidelines 14 Caution Risk of fire flammable materials ...

Страница 5: ...estoredinaroom without continuously operatingignition sources forexample openflames an operatinggasapplianceoranoperating electric heater The appliance shall be stored so as to WARNING Beawarethattherefrigerantsmaynot contain anodour Compliance with national gas regulations shall beobserved Keepventilationopeningsclearof obstruction DO NOT pierce orburn Awarningthattheapplianceshallbestored inawel...

Страница 6: ...unitto see ifanythingis damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with otherheatingdevices thoroughlyventilate the room to avoid oxygen deficiency DO NOT climb onto or place objects on top of the outdoorunit DO NOT operate the airconditioner when using fumigant insecticides The chemicals may become layered with the unit and endangert...

Страница 7: ...operation Iftheair conditioner is usedunder differentconditions it may malfunctionor becomelessefficient COOL Mode HEAT mode DRY mode Indoor Temperature 17 32 C 62 90 F 0 30 C 32 86 F 17 32 C 62 90 F 0 50 C 32 122 F Outdoor Temperature 15 50 C 5 122 F 15 24 C 5 76 F 0 50 C 32 122 F low temperature cooling models Page 6 Indoor Unit Parts And Major Functions Unit Parts ...

Страница 8: ...densationmayformanddrip intothemachine Toresetthelouver pressthe manual button which will reset the horizontal louver settings Refrigerant Leak Detection System some models Intheeventofarefrigerantleak theLCDscreen willdisplay EC andtheLEDindicatorlightwill flash Energy Saving Tips DO NOT set the unit to excessive temperature levels While cooling close the curtains to avoid direct sunlight Doors a...

Страница 9: ...n Thisbuttonselectsthemodeinthefollowingorder AUTO FORCEDCOOL OFF FORCED COOL mode InFORCED COOL mode the Operation lightflashes The system will then turn to AUTO after it has cooled with a high windspeed for30 minutes The remote control will be disabled during this operation OFF mode When the panel is turned OFF theunit turns off and the remote control is re enabled Page 8 Manual Operations Manua...

Страница 10: ...er preventsdustandother particles from enteringtheindoor unit Dustbuildupcanreduce the efficiency of the air conditioner Foroptimum efficiency clean the air filtereverytwoweeksor morefrequentlyifyouliveinadustyarea Replace the filter with a new one if it s heavily clogged and cannot becleaned Fig 4 2 Page 9 Care and Maintenance Removing and cleaning the filter can be performed by a certified techn...

Страница 11: ...les blocking the vents of both the indoor and outdoor units 2 Clean the air filter and the front grille of the indoorunit Reinstalltheclean dryairfilterin its originalposition 3 Turnonthemainpowerswitchatleast12 hours prior to operating the unit Storing the Unit While Not In Use 1 RuntheapplianceonFANmodefor12hours in a warm room to dry it and prevent mold 2 Turn off the appliance and unplug it 3 ...

Страница 12: ...set temperaturehas beenreached atwhich pointtheunitturnsoff the compressor Theunitwillresumeoperatingwhenthetemperaturefluctuates again The indoor unit emits white mist Inhumidregions alargetemperaturedifferencebetweentheroom sairand the conditioned air can cause white mist Both the indoor andoutdoorunits emit white mist WhentheunitrestartsinHEATmodeafterdefrosting whitemistmaybe emitted due to mo...

Страница 13: ... or outdoor unit is dirty Clean the affected heat exchanger The air filter is dirty Remove the filter and clean it according to instructions The air inlet or outlet of either unit is blocked Turntheunitoff remove theobstruction and turn it back on Doors and windows are open Makesurethatalldoorsandwindowsare closed while operating the unit Excessiveheat isgeneratedby sunlight Close windows and curt...

Страница 14: ...on 10 Off E9 10 Overload protection 1 On F0 11 Outdoor temperature sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge air temperature sensor error 4 On F3 14 Outdoor EEPROM Electrically Erasable Programmable Read Only Memory error 5 On F4 15 Outdoor fan speed DC fan motor only malfunction 6 On F5 16 Inverter module IPM protection 1 Flash P0 17 High Low voltage protec...

Страница 15: ...pal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will also take back the old appliance free of charge Sell the appliance to certified scrap metal dealers Thedesignandspecificationsaresubjecttochangewithoutpriornoticeforproduct improvement Consult with the sales agency or manufacturer for details QSBPQ...

Страница 16: ......

Отзывы: