Please take a minute to read carefully the system connection instructions listed below. 

1.

 

Firmly insert the Komodo board to PCIe connector of the motherboard. 

2.

 

Align  the  QSFP+/SFP+  transceiver  in  front  of  the  module’s  transceiver  socket  opening  and 

carefully slide the QSFP+/ SFP+ transceiver into the socket until the transceiver makes contact 

with the socket electrical connector. 

3.

 

Insert the fiber cable into the module, by firmly pushing each cable into the module, until  you 

will hear a click. 

4.

 

Connect the Power Adaptor to the JetCam power supply connector. 

5.

 

Turn the camera and the computer on and start your Vision Point software application. 

 

An example of JetCam system connection is described in the image below:  

Komodo Fiber

Frame Grabber

JetCam Camera

Fiber cable

(up to 80 km)

Power 

supply

 

Figure 2 : JetCam Camera system connection diagram

 

For more detailed information please refer to JetCam User Guide documentation. 

 

 

 

 

Introduction 

Содержание JetCam

Страница 1: ...ems GmbH Geisenhausenerstr 18 81379 Munich Germany 49 89 780 2970 info skyblue de www skyblue de In Great Britain Zerif Technologies Ltd Winnington House 2 Woodberry Grove Finchley London N12 0DR 44 1...

Страница 2: ...RE 3 JETCAM CAMERA SIDE VIEW W O LENS 4 FIGURE 4 DARK FIELD CALIBRATION STEPS 5 FIGURE 5 FLAT FIELD CALIBRATION STEPS 6 FIGURE 6 UNIFORM LIGHT SOURCE BEFORE VS AFTER FLAT FIELD CALIBRATION 6 FIGURE 7...

Страница 3: ...photo response non uniformities PRNU and or artifacts caused by the illumination and illumination optics These application notes describe how to calibrate the flat field functions and how to use them...

Страница 4: ...with the socket electrical connector 3 Insert the fiber cable into the module by firmly pushing each cable into the module until you will hear a click 4 Connect the Power Adaptor to the JetCam power...

Страница 5: ...brate It only requires a reference image to be recorded without illumination on the image sensor Follow this steps to perform dark field calibration process 1 For dark field calibration the light shou...

Страница 6: ...optimal result Follow this steps to perform flat field calibration process 1 Prepare light source Uniform light should be applied across the sensor This can be achieved by removing the lens and settin...

Страница 7: ...lable gain is not sufficient to correct for the difference between the weakest and brightest illuminated pixel segment a flat field cannot be achieved Figure 6 Uniform light source before vs after fla...

Страница 8: ...arameter configurations In addition a Default UserSet is available so it will be possible to revert back to default factory settings 1 Selection between the different available user configuration Defa...

Страница 9: ...and loading user set parameter configurations for a specific camera using Vision Point application Save User Set 1 Calibrate the desired camera parameters in Camera tab 2 Open User Set Control catego...

Страница 10: ...Volatile memory save function call sequence 1 UserMemoryBulkErase erase all user non volatile memory 2 UserMemoryPageSelector select page 255 0 in memory 256 bytes for each page 3 UserMemoryPageAll ar...

Отзывы: