2 0 H a M e s i l a S t . , N e s h e r 3 6 8 8 5 2 0 , I s r a e l
P O B 2 5 0 0 4 , H a i f a 3 1 2 5 0 0 1 , I s r a e l
T e l : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 0 0 F a x : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 1 1
Page no. 39 | Configuration Interface
6.11.2
P-Iris Setup
Please note that a camera must be ordered with the P-Iris option and P-Iris cable assembly in order for the P-Iris
lens to operate.
Figure 24 – Iron CoaXPress with P-Iris
Iron CoaXPress cameras have integrated Gen<i>Cam parameters for controlling P-Iris lenses.
1.
Mount the P-Iris lens and connect it to the GPIO while the camera is turned off.
2.
Set “LensSelector” as “P-Iris” to select P-Iris control.
3.
Initialize the P-Iris using “LensInit” command. The P-Iros will calibrate and move to initial position.
4.
After a successful initialization, the “LensIrisControl” category will be available to control the iris motor.
“LensIrisSpeed” can be used to increase the iris response speed (a value that is too low may result in
skipped steps.)
“LensIrisPositionMin” and “LensIrisPositionMin” can be set to limit step range of the iris motor (refer to
the lens’s manual for step range).
5.
Recommended: Use the “UserSetSave [UserSetSelector]” command to save this preset and remove the
need to initiate the P-Iris in future sessions.
Figure 25 – Lens Iris Control parameter configuration in GenICam Browser