8 Terms and conditions of warranty

8 Terms and conditions of warranty

The following warranty conditions apply to this KaVo medical device:

KaVo provides the end customer with a warranty of proper function and guar-
antees zero defects in respect of material and processing for a period of 10 re-
processing cycles / applications or 12 months from the date of the invoice, sub-
ject to the following conditions:
In case of justified complaints, KaVo will honour its warranty with a free re-
placement or repair. Other claims of any nature whatsoever, in particular with
respect to compensation, are excluded. In the event of default, gross negli-
gence or intent, this shall only apply in the absence of mandatory legal regula-
tions to the contrary.
KaVo shall not be liable for defects and their consequences that have arisen or
may arise from natural wear, improper handling, cleaning or maintenance, non-
compliance with operating, maintenance or connection instructions, calcination
or corrosion, contaminated air or water supplies or chemical or electrical factors
deemed abnormal or impermissible in accordance with KaVo's instructions for
use or other manufacturer's instructions. The warranty granted does not usually
extend to lamps, optical fibres made of glass and glass fibres, glassware, rub-
ber parts, and the colourfastness of plastic parts.
All liability is excluded if defects or their consequences originate from manipula-
tions or changes to the product made by the customer or a third party that is
not authorised by KaVo.
Warranty claims will only be accepted if the product is submitted along with
proof of purchase in the form of a copy of the invoice or note of delivery. The
dealer, purchase date, type, and serial number must be clearly evident from
this document.

23 / 26

Содержание 1.010.0287

Страница 1: ...Instructions for use PROPHYflex 4 Perio Kit 1 011 9403 Refill PROPHYflex perio tip 1 010 0287...

Страница 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 88400 Biberach Germany Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer KaVo Dental GmbH Bismarckring 39 88400 Biberach Germany www kavo com...

Страница 3: ...eps in accordance with ISO 17664 16 6 1 Preparations at the site of use 16 6 2 Pre cleaning 16 6 3 Manual Reprocessing 17 6 3 1 Manual external cleaning 17 6 3 2 Manual internal cleaning 17 6 3 3 Manu...

Страница 4: ...se ship your product to the KaVo Original Factory Repair using www kavobox com KaVo Technical Service If you have any questions or complaints please contact the KaVo Technical Service 49 0 7351 56 100...

Страница 5: ...medical devices Transportation and storage conditions Temperature range Transportation and storage conditions Air pressure Transportation and storage conditions Humidity Protect from moisture Keep dr...

Страница 6: ...4 Perio Kit 1 011 9403 Refill PROPHYflex perio tip 1 010 0287 1 User instructions 6 26 CAUTION In cases which if not prevented can lead to minor or moderate in jury NOTICE In cases which if not preven...

Страница 7: ...ated by the manufacturer If you deviate from this procedure it is essential to make sure that the re processing is effective Reprocess the product and accessories appropriately before disposal If ther...

Страница 8: ...ccessories or un authorised modifications of the device could lead to injury Only use accessories that have been approved for combination with the product by the manufacturer Only use consumables that...

Страница 9: ...0g Perio Powder PROPHYflex perio tip Refill REF 1 010 0287 3 2 1 Index 10x perio tip 1x Wrench 1x Nozzle pin The markings of the PROPHYflex perio tip are based on the WHO index 3 1 Intended use Indica...

Страница 10: ...parties from hazards to prevent contamination from the product 3 2 Transportation and storage conditions NOTICE Startup after refrigerated storage Malfunction Prior to startup strongly refrigerated pr...

Страница 11: ...io tip like injection needles in a closed container See also 2 6 Reprocessing steps in accordance with ISO 17664 Page 16 4 1 Inserting the adaptor into the PROPHYflex CAUTION Adapter falling off durin...

Страница 12: ...perio tip before each treatment and check if it is seated firmly Before each treatment make sure that the perio tip works properly Note In order to screw it on hold the wrench with 2 fingers in the r...

Страница 13: ...x perio tip 1 010 0287 4 Startup and shut down 4 4 Removing the PROPHYflex perio tip Carefully pull the PROPHYflex perio tip out of the wrench Take the adapter off Unscrew the adapter in counterclockw...

Страница 14: ...wder slowly to avoid the formation of dust Screw the container filled with the PROPHYflex Perio Powder onto the PRO PHYflex Settings on the powder jet unit Aim the jet nozzle at a wet washbasin from a...

Страница 15: ...cation Apical focus Root caries Treatment procedure 1 Introduce the perio tip to the floor of the pocket then pull the perio tip out by 1 2 mm 2 Start up the PROPHYflex with the foot control 3 Using s...

Страница 16: ...tip Page 12 Note Hardened or damaged adaptor O rings need to be replaced Reprocess the medical device as soon as possible after treatment The medical device must be dry when transported to reprocessin...

Страница 17: ...4 perio tip is not applicable For ef fective reprocessing after non fixating pre cleaning the inside of the device must be subjected to automated cleaning in a cleaning and disinfection unit in accor...

Страница 18: ...Manual drying of the PROPHYflex 4 perio tip is not applicable For effective re processing the inside of the device must be subjected to automated cleaning in a cleaning and disinfection unit in accor...

Страница 19: ...aning adapter PROPHYflex 4 long Mat no 3 004 6640 on the receptacle for INTRA connectors 6 4 2 Automated internal and external cleaning and internal and external disinfection KaVo recommends thermodis...

Страница 20: ...suitable for the sterilisation procedure The medical device must be packed before sterilisation 6 8 Sterilisation Sterilisation in a steam steriliser autoclave in accordance with EN 13060 EN ISO 1766...

Страница 21: ...s in accordance with ISO 17664 6 9 Storage Use according to the manufacturer s Instructions for Use 6 9 Storage Prepared products must be stored appropriately in a dry dark cool room such that they ar...

Страница 22: ...from specialised dental dealers Adapter perio tip 1 011 9400 Key 2 000 0901 Wrench for cannula 3 004 6351 Nozzle pin 0 410 0911 PROPHYflex perio tip Refill 10 pcs 1 010 0287 Cleaning adapter PROPHYfle...

Страница 23: ...aVo shall not be liable for defects and their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connec...

Страница 24: ......

Страница 25: ......

Страница 26: ...1 013 3754 bd 20220223 02 en...

Отзывы: