Kavan V20 Скачать руководство пользователя страница 7

7

•  The receiver is now ready for use.
•  If redundant connection is required, repeat for receivers 2 and 3. 

ACCST D16 protocol

The ACCST D16 protocol does not use a registration system, but only a pairing system.

1.  Turn off power to the receiver.
2.  Selecting [Pairing], a pop-up window will appear with a selection of channels, once selected, start the pairing 

process. Every few seconds, a „Pairing“ voice alert will sound to confirm that you are in pairing mode. The 

pop-up window will display the message „ Pairing ...“.

3.  Turn on the receiver, while holding the pairing button F/S. A window will appear with the message „ Select 

Device“ and the name of the receiver you just turned on.

4.  Scroll to the receiver name and select it. A window will appear with a message that the pairing was successful. 

Switch off the transmitter and receiver. Switch on the transmitter and then the receiver. If the green LED on the 

receiver is lit and the red LED is not lit, the receiver is connected to the transmitter. The pairing of the receiver 

and transmitter will not need to be repeated unless one is replaced. 

•  The receiver will only be controlled by the transmitter it is paired to. Other transmitters in its vicinity will not 

affect its operation.

•  The name of the RX1 receiver will now be displayed next to the selected receiver.
•  The receiver is now ready for use. 

FAIL-SAFE EMERGENCY RATES

When Fail-safe is enabled, 3 modes are available: No signal, Hold, Custom.

No signal:

 when signal is lost, the receiver does not send a control signal to the rates on any channel. To use this type, 

select it from the menu and wait 9 seconds for the Fail-safe setting change to take effect.

Hold:

 the receiver maintains the rates as they were before the signal was lost. To use this type, select it from the 

menu and wait 9 seconds for the Fail-safe setting change to take effect.

Custom:

 the receiver keeps the rate value on all channels as you preselect it. Select the Fail-safe setting menu. 

Switch from Disconnect/Hold/Not Set to „Custom“. Select the channel for which you want to set fail-safe rates and 

confirm the selection. Then set the rates on each desired channel and confirm the selection. Wait 9 seconds for the 

Fail-safe setting change to take effect.

Note: 

If the fail-safe rates are disabled on the transmitter, the fail-safe rates set on the receiver will automatically 

be used. The S.BUS connector does not support „Disconnect“ mode, and will always use „Hold“ or „Custom“ mode. 

RANGE CHECK

A pre-flight range check should be performed before each flight. Select the „RF System“ section, select either the 

internal or external module, select „Action“, then „Range Check“ and confirm the selection. In range check mode, the 

effective range of the transmitter is reduced to 1/30. Press „Range Check“ again to return to normal mode.

A „Range Check“ voice alert will sound every few seconds to confirm that you are in range check mode. A pop-up 

window on the display will show the receiver UID and the VFR% and RSSI values to evaluate the reception quality. 

Under ideal conditions, when the transmitter and receiver are both 1 m above the ground, the Alarm should appear at 

a distance of approximately 30 m from each other.

PRINCIPLES OF SAFE OPERATION

Operating the models can be dangerous if you do not follow the appropriate safety guidelines. Here are some of the 

most important recommendations to help ensure safe operation.

•  Before taking off, make sure the model responds properly to the gimbal movements on the transmitter. Also 

make sure all switches and other controls are functioning properly. If you find any problems, do not fly the model 

until all functions are working properly.

Содержание V20

Страница 1: ...Twin 2 4GHz ACCESS ACCST D16 QUICK START GUIDE ENGLISH...

Страница 2: ...RF protocol 2 4GHz simultaneous on two frequen cies Twin 2 4GHz Antenna two built in 2 4GHz antennas Dimensions 221 5 214 5 94 mm W H D Weight 1027 g including battery Operating system ETHOS Internal...

Страница 3: ...display backlight intensity Calibration of gimbals Sound and vibration warning alerts Range check Setting operation with 3 receivers 1 4 3 LCD 800 480 px 2 2 way switch 6 3 3 way switch 5 4 3 way swi...

Страница 4: ...Handle 28 Module connection case 29 Battery case 30 Grips 31 Momentary buttons 32 External antenna 2 33 Audio jack 3 5 mm 34 USB C 35 MicroSD slot 36 Smart port 37 Trainer port 38 External antenna 1...

Страница 5: ...SHING charging error NAVIGATION CONTROLLERS The left navigation buttons represent the MODEL SYSTEM DISPLAY BACK functions The right navigation knob is used to control the display and performs the same...

Страница 6: ...UID must be changed usually 0 for CH1 8 1 for CH9 16 and 2 for CH17 24 Note that this UID cannot be read back from the receiver so it is a good idea to tag the receiver 4 Press the Register button to...

Страница 7: ...o use this type select it from the menu and wait 9 seconds for the Fail safe setting change to take effect Custom the receiver keeps the rate value on all channels as you preselect it Select the Fail...

Страница 8: ...the throttle to neutral in case of an emergency Always check the charge level of the transmitter and receiver batteries before each takeoff Low voltage will cause loss of control of the model and a c...

Страница 9: ...ranty certificate entitles you to a free warranty repair of the product supplied by KAVAN Europe s r o within a period of 24 months The warranty does not cover natural wear and tear due to normal use...

Страница 10: ...KAVAN Europe s r o 420 466 260 133 info kavanrc com www kavanrc com Doubravice 110 533 53 Pardubice Czech Republic...