10.1.2 Rear View
⑤
Fig. 12: RRU 1400
No.
Name
Function
①
ANT1 ... 4
4x FAKRA, 50 Ohm, to connect an antenna
②
GPIO
to detect external sensors and to control external actors; see also
16.6 GPIO
Functions
③
LAN/PoE
main Ethernet port with PoE connectivity
● to control the reader
● to provide power supply over Ethernet
④
PWR
to connect to a DC power supply, 10–30 V
⑤
4 x tapped holes to connect to the MK-WPM3-OSS Outdoor wall/pole mount kit
(order number 52010351 or 52010262)