58
Technical Bulletins
The following pages include Spectra
’
s most commonly
-
used technical bulletins, covering tests,
adjustments, troubleshooting, and common points of confusion. Many more technical bulle-
tins are available on the Spectra website, www.spectrawatermakers.com.
ACCUMULATOR PRESSURE
Your Bimini 300 is supplied with a pressure accumulator tank (PL
-
ACC
-
TK) installed in the feed
water line between the feed pump and the Clark Pump.
The purpose of the feed line accumulator is to reduce the spikes in the feed pressure caused
by the cycling of the Clark Pump. If the accumulator is not properly charged it can lead to pres-
sure spikes and system shut down. The accumulator has a Schrader air valve, like a car tire,
which allows the internal air bladder of the accumulator to be pre
-
charged. The accumulator
should be pumped up to about 60 psi (4.1 bar) for best results. Add air using a tire pump or air
compressor. You can experiment with the exact pressure that will give the best pulsation
dampening on your installation.
Schrader valve
Содержание Spectra Bimini 300
Страница 2: ...2...
Страница 4: ...4...
Страница 6: ...6...
Страница 8: ...8...
Страница 10: ...10 Installation Notes...
Страница 19: ...19 John Guest Super Speedfit Fittings...
Страница 67: ...67 Wiring Schematic...
Страница 75: ...75 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB10 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used...
Страница 77: ...77 Parts 1 SO HPP PR10...
Страница 78: ...78 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Страница 79: ...79...
Страница 83: ...83...
Страница 85: ...85...
Страница 88: ...88...