background image

TEICH-AIRE MANUAL

6

It is your responsibility to:

•  Regularly inspect and make necessary repairs to the compressor in order to maintain proper 

operations.

•  Make sure that pressure is released from product before performing maintenance.

This compressor is oil-less and requires NO lubrication.

Check the intake filter after first 500 hours of operation.

Clean the filter and determine how frequently filters should be checked during future operation, being 

aware that environmental changes during different seasons can affect operation (heavy pollen in spring or 

increased dust particulate in a dry summer). Kasco recommends checking the filter every month. Clean or 

replace filter elements as necessary. This one procedure will help ensure the product’s performance and 

service life. Failure to maintain clean air filter elements will lead to clogging, which will cause excessive heat 

and premature failure of the compressor.

Filter maintenance:

•  Disconnect electrical power supply to unit.

•  Vent all air lines.

• 

Remove filter cover.

• 

Remove and replace filter element as necessary.

• 

Replacement filter elements are readily available. Please contact your local Kasco distributor and ask for 

the replacement air filter element: part #771014 for KM-60 or KM-120 Models, or part #771018 for KM-

200 Models 

• 

Reinstall filter element and cover.

MAINTENANCE

WARNING

Allow product surfaces to cool before handling. 

Product surfaces become very hot during oper-

ation. 

Wear proper eye protection. Air stream from 

product may contain solid or liquid material that 

can result in eye or skin damage. 

Clean this product in a well-ventilated area.

Failure to follow these instructions can result in 

burns, eye injury, or other serious injury.

Injury Hazard

WARNING

Electrical Shock Hazard

Electrical Shock Hazard

Disconnect electrical power supply cord before 

performing maintenance on this product.

If this product is hardwired into the system, dis-

connect electrical power at the circuit breaker or 

fuse box before performing maintenance.

Failure to follow these instructions can result in 

fire, electrical shock, or death.

Back to Contents

Содержание KM-120

Страница 1: ...00 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 771068 Document version 2021 1 0 KM SERIES COMPRESSOR Teich Aire ...

Страница 2: ... TABLE OF CONTENTS 715 262 4488 kascomarine com sales kascomarine com QUESTIONS Product Overview 2 Installation 3 Electrical 4 Operation 5 Maintenance 6 Troubleshooting 7 Warranty 8 Other Repairs 9 Repair Contact Form 10 ...

Страница 3: ...armful elements of the outdoor environment Ambient air temperature readings taken 4 away from any surface of the compressor must not exceed 104 F 40 C Ensure that adequate ventilation and cooling air flowing across the compressor is available to keep the compressor from overheating which can cause premature damage Mount the compressor to a stable rigid operating surface Using the provided shock mo...

Страница 4: ... air filter in one inlet port Kasco recommends installing a pressure relief valve in an outlet port to bleed off excess pressure in case of a blocked line Check valves may be required to prevent back flow through the compressor KM 60 KM 60HC EX Pressure relief valve Air filter IN Barb fitting EX EX Pressure relief valve Air filter IN Barb fitting EX EX Pressure relief valve Air filter connected to...

Страница 5: ... condition or is inadequate for the requirements of this product Failure to follow these instructions can result in fire electrical shock or death Make sure that the power supply voltage agrees with that listed on the product nameplate All cords with plugs must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Hardwired installation...

Страница 6: ... tor may exceed 70 dBA Failure to follow these instructions can result in burns eye injury or other serious injury Injury Hazard OPERATION It is your responsibility to operate this compressor at recommended pressures and permissible ambient temperatures Do not start against a vacuum or pressure load If the motor fails to start or slows down significantly under load shut off and disconnect from the...

Страница 7: ...electrical power supply to unit Vent all air lines Remove filter cover Remove and replace filter element as necessary Replacement filter elements are readily available Please contact your local Kasco distributor and ask for the replacement air filter element part 771014 for KM 60 or KM 120 Models or part 771018 for KM 200 Models Reinstall filter element and cover MAINTENANCE WARNING Allow product ...

Страница 8: ...lve is set too high Inspect and adjust Relief valve is set too low Inspect and adjust Plugged pressure line Inspect and repair Low voltage will not start Check power supply Incorrect voltage Check power supply Worn cup piston hitting cylinder Replace Cylinder misadjustment Realign Leaky hose or check valve Replace Dirt or liquid on top of piston Inspect and clean Motor not wired correctly Check wi...

Страница 9: ...it may be sent to any Kas co Authorized Repair Center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information and or Repair Form or call to locate your nearest Authorized Repair Center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your local distributor with the shipment If no repair ...

Страница 10: ...amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will restore the unit as closely as possible to the condition in which we found it and ship at the customer s expense including shipping and handlin...

Страница 11: ...a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the c...

Отзывы: