background image

KD3000 Series Mini Inverter

Simple Manual

6w~200w Mini Inverter

Green.Intelligent.Energy-Saving

Shenzhen Karda Electric Co.Ltd

www.szkarda.com

Содержание KD3000 Series

Страница 1: ...KD3000 Series Mini Inverter Simple Manual 6w 200w Mini Inverter Green Intelligent Energy Saving Shenzhen Karda Electric Co Ltd www szkarda com...

Страница 2: ...the input power is off Be sure to install the terminal cover before turning on the power When removing the cover be sure to turn off the power Grounding terminal must be grounded reliably Do not touc...

Страница 3: ...put Terminals U V W 220V 3 Phase output Terminals Grounding V Basic Wiring Diagram Sort Terminal Name Function Description Specification Communi cation 485 RS485 communication port RS485 differential...

Страница 4: ...rogramming see terminal function parameters P4 group input terminal functions Common port COM X2 Multifunctional input terminal 2 X3 Multifunctional input terminal 3 Power source 10V 10Vpower source S...

Страница 5: ...on control panel single display valid 1 key on control panel single display valid Panel digital potentiometer key on control panel double display valid 2 Digital setting 1 control panel given 3 Digit...

Страница 6: ...80 0 Acc Dec time P0 14 P0 15 90 0 1 60 0 P0 16 Acc Dec time unit 0 Second 1 Minute 0 0 P0 17 Acc time 1 0 1 6000 0 0 1 20 0 P0 18 Dec time 1 0 1 6000 0 0 1 20 0 P0 19 Upper limit freq Lower limit fre...

Страница 7: ...start from start freq 2 Track speed then start 1 0 P2 01 Start freq 0 40 20 00Hz 0 01Hz 0 50Hz P2 02 Start freq running duration 0 0 30 0s 0 1s 0 0s P2 03 DC brake current as start 0 15 1 0 P2 04 DC...

Страница 8: ...7 Acc Dec time terminal 2 8 Acc Dec time terminal 3 9 3 wire control 10 Free stop input FRS 11 External stop command 12 Stopping DC brake input command DB 13 Inverter running prohibited 14 Freq increa...

Страница 9: ...ction parameter Func Code Name Range Min Unit Factory default Modify P6 00 Last fault record Last fault record 1 0 P6 01 Output freq in last fault Output freq in last fault 0 01Hz 0 P6 02 Set freq in...

Страница 10: ...too big Add suitable braking device Inverter capacity is too low Select inverter with proper capacity E 03 Over current at constant speed running Load mutation Check load Acc or Dec time is too short...

Страница 11: ...ns voltage General motor runs at low speed with heavy load for long term Use a special motor for long term running Wrong setting of motor overload protection factor Set the factor right Motor chocked...

Страница 12: ...ll input power source filter DSP read write error Reset or contact supplier E 17 EP2PPROM error Read write error of control parameter press key to reset or install input power source filter E 18 Motor...

Страница 13: ...of fault and clearing otherwise the inverter may be damaged 2 If it can t be reseted or fault occurs again after reset please check the cause of fault continuous reset may damage inverter 3 Reset the...

Отзывы: