Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Technical data
Subject to technical modifications.
The device does not dis-
pense enough water.
The filter cartridges are clogged.
Check compliance with the change inter-
vals of the filter cartridges, replace the cor-
responding filter cartridges if necessary.
If the change interval has not yet been
reached, first replace the left filter cartridge
and vent the device, see Chapter
.
If the device continues to dispense too little
water, replace the middle filter cartridge in
the same way.
If the device continues to dispense too little
water, replace the right filter cartridge in the
same way.
The water supply is reduced.
Check the position of the cold water inlet
angle valve and the stop valve, open fully if
necessary.
Check the condition of the lines, repair
kinks and damage if necessary.
If the malfunction persists, contact the ser-
vice department.
The water inlet pressure is too low.
Adjust the water inlet pressure to 4 bar on
the pressure reducer of the building's
drinking water installation or on the sepa-
rate pressure reducer.
If the malfunction persists, contact the ser-
vice department.
The device does not re-
lease any water.
The water supply is interrupted.
Check the position of the cold water inlet
angle valve and the stop valve, open fully if
necessary.
Check the condition of the lines, repair
kinks and damage if necessary.
If the malfunction persists, contact the ser-
vice department.
The water quality is im-
paired (contamination,
bad smell / taste).
The filter capacity of a filter cartridge is
exhausted or the change interval has
been exceeded.
Replace the corresponding filter cartridge.
If the change interval has not yet been
reached, first replace the left filter cartridge
and vent the device, see Chapter
.
If the water quality is still affected, replace
the middle filter cartridge in the same way.
If the water quality is still affected, replace
the right filter cartridge in the same way.
Fault
Cause
Rectification
Device performance data
Water supply pressure
MPa
(bar)
0,1-0,4
(1-4)
Water supply temperature
°C
5-38
Ambient temperature
°C
4-40
Water dispenser (depending on supply pressure
and filter status)
Filtered water
l/min
2
Dimensions and weights
Width
mm
377
Depth
mm
168
Height
mm
421
Weight
kg
5,66