OPERATION
Version 03/2008
WATERCLEAN 1600
- 62 -
3.4.3.2
Switching OFF in Manual Operation Mode
1.
Fully turn the hand-wheel (43/1) slowly in the "OPEN" direction.
2.
Press the "Stop" button (49/8).
➜
Control valve V06 opens; "Control valve V06 open" lamp
(49/14) flashes. When the valve is open, the lamp lights con-
tinuously.
NOTE
The opening duration can take up to 3 minutes.
➜
Raw water pump stops, lamp (49/13) goes out
➜
Luminous lamp "Start" (49/11) illuminates
3.
Turn main switch (49/16) to position
O
"OFF".
➜
All displays and lamps go out
WARNING
If the systems stands still for a longer period
(> 60 h) preservation measures are to be taken
according to Section 3.5.3.
4.
Return all valves to position
I
for pass
1
position.
3.4.3.3
Switching ON in Manual Operation Mode as Emergency Function
For some sensory malfunctions, e. g., drinking water flow meter,
switching on the system in "Emergency operation” is possible as fol-
lows.
1.
Before switching on, make sure that the levers and the hand-
wheel of the double-pass operating panel are in position
I
2.
Leave the concentrate return line as in automatic operation.
3.
Set the main switch (49/16) to position
I
"ON".
➜
The reactions are the same as in Section 3.4.2.1 "Switching
ON in automatic operation mode"
4.
Turn the "Program" selector switch (49/12) to position
1
"Man-
ual".
5.
Press the luminous "Start" button (49/11).
➜
On the display of the control panel (49/7), "Hand" and after-
wards "Pass 1" is indicated
➜
The "Raw water pump ON " lamp (49/13) lights up
6.
With button "
▼
" (44/3) on the control panel, switch to the "Pass 2"
menu.
7.
Press button "2" (44/5) until the output value of approx. 1 600 l/h
is indicated on the "Pass 2" menu.
If the value is exceeded, press button "4" (44/4) in order to reduce
the output value.
➜
The lamps "Control valve V06 closed" (49/15) respectively "
Control valve V06 open" (49/14) flash during the manual con-
trol procedure
Содержание WATERCLEAN 1600
Страница 2: ......
Страница 14: ...GENERAL Version 03 2008 WATERCLEAN 1600 8 ...
Страница 28: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 22 Fig 13 Anti scalant mounting kit 1 2 ...
Страница 48: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 42 ...
Страница 82: ...OPERATION Version 03 2008 WATERCLEAN 1600 76 ...
Страница 106: ...APPENDIX Version 03 2008 WATERCLEAN 1600 100 ...
Страница 108: ......
Страница 110: ......