When unpacking the product, make sure 
that no accessories are missing and that 
none of the package contents have been 
damaged. If you detect any transport dam-
ages please contact your dealer. 

Illustrations on Page 3

* depending on model

Flashing values are changed by means 
of the arrow keys.

OK button

 completes an entry and 

switches to the next entry field. It also 
completes the entry in the last entry 
field and then switches into the auto-
matic mode.

esc button

 discards an entry and 

switches to the previous entry field or 
exits the entry at the first field and 
switches into the automatic mode.

If no button is pressed for 30 seconds, 
the appliance returns to the automatic 
mode.

During the initial startup, it can individually 
be selected for each water outlet how it is to 
be operated: 

In order to get to the automatic mode, at 
least 1 sensor must be used or the de-
vice must be taught for time control. 
Otherwise the water outlets for auto-
matic watering are inactive.

Sensor-controlled

The sensor is taught during the 60-sec-
ond countdown, i.e. the radio signal is 
detected automatically.

Time-controlled

The teaching process of the sensor is 
cancelled with the 

esc/menu button

 

during the 60-second countdown.
In this case, the moisture tripping limit 
at the control unit can not be set.

Locked / inactive

The 60-second countdown passes 
completely without the recognition of 
the sensor or the esc/menu button be-
ing pushed, then the water outlet is in-
active. After deactivation of water outlet 
1, the countdown for outlet 2 can be en-
abled with the OK button.

Description of the display

1

Radio signal and field strength

2

Battery status sensor

3

Tripping limit soil moisture

4

Measured soil moisture

5

Sensor 1 / water outlet 1

6

Irrigation / manual irrigation

7

Sensor 2 / water outlet 2*

8

Battery status control unit

9

Time / time of irrigation

10 Irrigation duration

11 Irrigation delay (eco!ogic function)

12 Break button and setting of the time

13 menu / esc button

14 OK button

15 Arrow keys

Description of the Appliance

A

G 3/4 reducer

B

G1 water connection with pre-filter

C

Top part of the casing for two-channel 
appliance*

D

G 3/4 hose connection

E

Tap connection adapter

F

Control unit 

G

Battery compartment

H

Display

I

Keypad

J

Sensor 1

K

Sensor 2*

L

Sensor cap

M

Cover sensor pad

N

Sensor pad

O

Eyelet for theft protection*

P

Notches for wall mounting

Q

Top part of the casing for single-chan-
nel appliance* (rear view)

General information on the

 operation

Basic functions of the enter keys

13

EN

Содержание SensoTimer ST6 Duo eco!ogic

Страница 1: ...1 SensoTimer ST6 eco ogic SensoTimer ST6 Duo eco ogic 59665320 08 18 Deutsch 4 English 11 Fran ais 18 Italiano 25 Nederlands 32 Espa ol 39 Portugu s 46 Dansk 53 Norsk 60 Svenska 67 Suomi 74 81 Magyar...

Страница 2: ...1 2 sensor eco ON OFF Ok esc menu 24 d min 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2...

Страница 3: ...A C B D D E E F G F H I J K M L N O O P P Q D E B A 3...

Страница 4: ...the ingredients at www kaercher com REACH At the end of the operating instructions you will find a selected list of spare parts that are often required You can procure the spare parts and the at tach...

Страница 5: ...tap Do not pull on the attached hose Do not install the irrigation device near heat sources max ambient tempera ture 60 C Caution Only use 9V batteries type 6LR61 Al kaline Do not use rechargeable bat...

Страница 6: ...ss of the sensor is cancelled with the esc menu button during the 60 second countdown In this case the moisture tripping limit at the control unit can not be set Locked inactive The 60 second countdow...

Страница 7: ...f the sen sor cap Figure 5 Contact radio signal As soon as the contact of the radio sig nal is established the symbol for the ra dio signal appears permanently It is now guided through the setup se qu...

Страница 8: ...nd confirm your selection with the OK but ton The valves are opened closed by re peatedly pressing the arrow keys The esc button terminates the manual irrigation and switches back into the au tomatic...

Страница 9: ...Replace the batter ies of the control unit and the sensor as well as the sensor pad annually Completely drain all water from the irri gation device Remove the batteries from the sensor and the control...

Страница 10: ...Alkaline or clean contacts Radio signal battery symbol and moisture val ue of the sensor are not indicated No radio communication be tween the control unit and the sensor The device is in its failure...

Отзывы: