background image

– 13

Illustration 

Place one foot on the bottom corner of the floor
cleaning cloth and lift the floor nozzle up.

NOTICE

Initially, the floor cleaning cloth's hook and loop fastener 
strip is very strong and cannot be removed from the 
floor nozzle easily. After the floor cleaning cloth has 
been used several times and washed, it is easier to re-
move from the floor nozzle and it has reached the opti-
mum adhesion.

Illustration 

During work breaks, hook the floor nozzle into the 
parking holder.

The carpet glider is used for freshening up carpets.

ATTENTION

Beware of damaging the carpet glider and carpet

Contamination on the carpet glider, as well as heat and 
moisture penetration, can result in the carpet being 
damaged.
Prior to the application, also check the heat resistance 
and impact of steam on the carpet at an insignificant 
spot using as small an amount of steam as possible. 
Observe the cleaning instructions from the carpet man-
ufacturer.Prior to using the carpet glider, make sure that 
the carpet has been vacuumed and that stains have 
been removed. 
Prior to application and following operating pauses, re-
move any possible water accumulation (condensate) in 
the appliance by means of evaporating the condensate 
into a drain (without floor cleaning cloth / with accesso-
ries).
Only use the carpet glider with a floor cleaning cloth on 
the floor nozzle.Steam clean with a weak steam stage 
when using the carpet glider.In order to prevent too 
much moistening and to avoid the risk of damage due to 
temperature effects, do not direct the steam continuous-
ly onto one spot (maximum 5 seconds).
Do not use the carpet glider on deep-pile carpets.

Illustration 

For fastening the floor cleaning cloth to the floor 
nozzle, please refer to chapter Floor nozzle.

Illustration 

Using a little force, allow the floor nozzle to slide 
into the carpet glider and engage there.

Start cleaning the carpet.

CAUTION

Beware of burns to your feet

The carpet glider can heat up during the steaming pro-
cess.Do not operate or remove the carpet glider bare-
footed or using open sandals.
Only operate or remove the carpet glider using suitable 
footwear.
Illustration 

Press the strap on the carpet glider downwards us-
ing your toecap.

Lift the floor nozzle upwards.

Rinse the steam cleaner boiler at the latest after 10 boil-
er fillings.

Fill the boiler with water and shake it strongly. This
dissolves lime scaling residing on the boiler bottom. 

Illustration 

Empty water out.

Note: 

If you always use usual commercial distilled water it is 
not necessary to descale the boiler.

As limescale builds up on the boiler walls, we recom-
mend to descale the boiler in the following intervals 
(RF=reservoir fillings):

Note

The hardness of the tap water can be inquired at your 
water management office or the municipal utilities.
Illustration 

Turn off the appliance.
See Chapter „Turning Off the Appliance“.

Allow device to cool down.

Remove the safety lock from the device.

Illustration 

Completely empty the water tank to remove exist-
ing water.

Use KÄRCHER decalcifying agents for descaling. 
Please follow the dosing instructions on the pack-
aging when preparing the descaler.

ATTENTION

Use caution when filling and emptying the steam clean-
er. The descaling solution can have an aggressive ef-
fect on delicate surfaces.

Completely empty the descaling solution after 8 
hours. A small amount of the solution will remain in 
the boiler. Therefore, you should rinse the boiler 
two to three times with cold water to remove any 
residues of the descaler.

Illustration 

Completely empty the water tank to remove exist-
ing water.

Removing the floor cleaning cloth

Parking the floor nozzle

Carpet glider

Fastening the carpet glider to the floor nozzle

Removing the carpet glider from the floor nozzle

Care and maintenance

Rinsing the boiler

Descaling the boiler

Degree of hardness

° dH

mmol/l

RF

I

soft

0- 7 

0-1,3

55

II

medium

7-14

1,3-2,5

45

III

hard

14-21

2,5-3,8

35

IV very hard

>21

>3,8

25

Содержание SC EasyFix ATK 2

Страница 1: ...SC EasyFix ATK 2 Operating Instructions Please read the operating instructions carefully before using the unit 59690370 07 19 ...

Страница 2: ...G 1 2 1 2 1 2 G L M J K 2 ...

Страница 3: ...O N 3 ...

Страница 4: ...re parts please visit www kaercher com The warranty terms published by the relevant sales company are applicable in each country We will repair potential failures of your appliance within the warranty period free of charge provided that such failure is caused by faulty material or defects in manufacturing In the event of a warranty claim please contact your dealer or the nearest authorized Custome...

Страница 5: ... to cool down before performing any maintenance work Repair works may only be performed by the authorized customer service The connection between the power cord and extension ca ble must not lie in water 몇 WARNING The appliance may only be connected to an electric sup ply that has been installed by an electrician in accordance with IEC 60364 The appliance may only be connected to alternating cur r...

Страница 6: ...must not be operated by children or per sons who have not been in structed accordingly This appliance is not intended for use by persons with limit ed physical sensory or men tal capacities or lacking expe rience and or skills unless such persons are accompa nied and supervised by a per son in charge of their safety or they have received precise instructions on the use of this appliance and have u...

Страница 7: ...pe 몇 CAUTION CAUTION Please read the operating in structions 몇 CAUTION Safety devices protect the user and must not be modi fied or bypassed The pressure controller keeps the boiler pressure dur ing the operation as constant as possible The heating is turned off if the maximum operating pressure of 4 bar is reached in the boiler and is reactivated in case of a pressure drop in the boiler due to st...

Страница 8: ...NGE A5 Safety cap A6 Holder for accessories A7 Storage holder for floor nozzle A8 Carrying handle A9 Accessories storage A10 Mains cable with mains plug A11 Running wheels 2 ea A12 Steering roller B1 Steam gun B2 Unlocking button B3 Selector switch for the steam volume with child protection B4 Steam lever B5 Steam hose A11 A6 A12 ...

Страница 9: ... C1 Detail nozzle C2 Round brush D1 Hand nozzle D2 Manual nozzle microfibre cover E1 Extension tubes two tubes E2 Unlocking button F1 Floor nozzle F2 Hook and loop fastener F3 Microfibre floor cloth F4 Carpet glider G1 Descaler F4 G1 ...

Страница 10: ... water 2 Screw in safety cap 3 Plug in the mains plug Turn on the machine The green and orange indicator lamps light up 4 Wait until the orange indicator lamp goes out 5 Connect the accessories to the steam gun The steam cleaner is ready to use Quick Reference 6 5 min 1 liter click ...

Страница 11: ... switch to the required steam volume While operating the steam switch always direct the steam gun at a separate piece of cloth until the steam is emitted evenly Note The heating of the steam cleaner is turned on in regular intervals during the operation of the appli ance in order to maintain the pressure in the boiler at a constant level When the heating is turned on the orange indicator lamp heat...

Страница 12: ...ly suit ed for cleaning difficult access locations joints fittings drains sinks toilets blinds and heaters Heavy lime scale can be drenched in vinegar prior to steam clean ing Let the vinegar penetrate for about 5 minutes Illustration Slide the spotlight nozzle onto the steam gun The round brush can be installed onto the detail nozzle as an accessory Attached brushes can therefore be used to remov...

Страница 13: ...cleaning the carpet 몇 CAUTION Beware of burns to your feet The carpet glider can heat up during the steaming pro cess Do not operate or remove the carpet glider bare footed or using open sandals Only operate or remove the carpet glider using suitable footwear Illustration Press the strap on the carpet glider downwards us ing your toecap Lift the floor nozzle upwards Rinse the steam cleaner boiler ...

Страница 14: ...ce Refill water Steam switch is secured with the lock child proof lock Move the selector switch for the steam volume to the front Press the steam gun until less water is emitted Descale the steam boiler Subject to technical modifications Care of the Accessories Troubleshooting Long heating up time Steam boiler is decalcified No steam No water in the steam boiler Steam lever cannot be pressed anymo...

Страница 15: ......

Страница 16: ...www kaercher com dealersearch Alfred Kärcher 6 Co KG Alfred Kärcher Str 28 40 71364 Winnenden Germany Tel 49 7195 14 0 Fax 49 7195 14 2212 ...

Отзывы: