English
5.906-508.0 Rev. 00 (11/10)
47
Note
The suction force can be adjusted by adjusting the
vacuum lip distance to the floor.
The wear and tear of the vacuum lips can be bal-
anced via this adjustment.
1 Floor nozzle
2 Adjusting screw
Î
Turn the adjustment screw in a clockwise direc-
tion.
The distance between the vacuum lips and the
ground increases.
Î
Turn the adjustment screw in an anticlockwise di-
rection.
The distance between the vacuum lips and the
ground decreases.
1 Floor nozzle
2 Locking
3 Front vacuum lip
Check the vacuum lips of the floor nozzle for wear
and tear / damage.
If necessary, replace the vacuum lips.
Î
Swivel the lock to the side.
Î
Pull the front vacuum lip out of the side of the
guide groove, and replace it.
1 Adjusting screw
2 Running roller
3 Rear vacuum lip
4 Floor nozzle
Î
Turn the adjustment screw in an anticlockwise di-
rection.
Î
Fold the casters up toward the top.
Î
Pull the rear vacuum lip out of the side of the guide
groove, and replace it.
Installation in reverse order
Note
The structured side of the vacuum lip must point out-
wards.
5.12 Floor nozzle
5.12.1Adjust the distance of the vacuum lips.
5.12.2Replacing the vacuum lips