Kaptur KP1200 Скачать руководство пользователя страница 1

KP1200 User Manual Version 1.0-EN 

www.kaptur-id.com

 

 

 

 
 

KP1200 elite 2D Barcode Scanner 

User Manual 

 
 
 
 
 
 
 

 

 
 

 

 

Содержание KP1200

Страница 1: ...KP1200 User Manual Version 1 0 EN www kaptur id com KP1200 elite 2D Barcode Scanner User Manual...

Страница 2: ...2 of 93 KP1200 User Manual Version 1 00 EN This page has been intentionally left blank...

Страница 3: ...he contents and the form of this document as well as to modify the product specifications at any time The information contained in this document is property of Trovi Technology to whom all rights are...

Страница 4: ...lection center to avoid damage to the environment or human health caused by uncontrolled disposal of waste and to promote the sustainable re cycling of materials Improper disposal of the product by th...

Страница 5: ...parameter setting by scanning a QR code barcode 13 3 3 Operate the scanner by receiving command via UART 14 3 4 Interface selection 14 3 5 RS 232 interface 15 3 6 USB interface 18 3 7 Scan mode some g...

Страница 6: ...QR Code 70 3 35 Data Matrix 71 3 36 Han Xin Code 72 3 37 Aztec Code 73 3 38 MicroQR Code 74 3 39 G1 G6 C1 C3 FN1 substitution string setting 75 3 40 G1 G4 string position Code ID position 82 3 41 Str...

Страница 7: ...Capability 1D UPC A UPC E UPC E1 EAN 13 EAN 8 ISBN Bookland EAN ISSN Code 39 Code 39 full ASCII Code 32 Trioptic Code 39 Interleaved 2 of 5 Industrial 2 of 5 Discrete 2 of 5 Matrix 2 of 5 Codabar NW7...

Страница 8: ...x 2 of 5 6 X Im Codabar 4 N Fm Code 128 1 K Cm UCC EAN 128 1 K Cm ISBT 128 1 K Cm Code 93 1 L Gm Code 11 4 V MSI Plessey 4 O Mm UK Plessey 1 U Mm China Post 11 2 T Im China Finance 10 2 Y Telepen 1 P...

Страница 9: ...200 User Manual Version 1 00 EN 9 of 93 2 Get started 2 1 Dimensions Stand is an optional 2 2 Parts of the scanner Figure 2 1 LED Beeper Scan window Trigger Release hole of the cable Cable interface p...

Страница 10: ...terminal 3 Windows will automatically detect the USB device Figure 2 3 2 4 2 Installation RS 232 1 Connect the RS 232 interface cable to the bottom of the scanner 2 Connect the other end of the inter...

Страница 11: ...KP1200 User Manual Version 1 00 EN 11 of 93 2 4 Assembling the Stand Note The stand is an optional accessory...

Страница 12: ...scan setting Scan the appropriate Single scan setting e g 0101D00 according to the user s demand Example To set Flow control to be XON XOFF Steps Scan the following barcode Multiple scan setting Step...

Страница 13: ...03 decimal 8002 0D0A hexadecimal 8202 01 decimal The customized QR code barcode contents and symbol are as following 0401D03 8002H0D0A 8202D01 2 Notes of making QR code barcode The model is chosen as...

Страница 14: ...mand 0x16 0x54 0x0D When the scanner received the above command it will start barcode scanning following the setting of Scan mode 2 Stop command 0x16 0x55 0x0D If the Scan mode is set as Alternate con...

Страница 15: ...mmunication If there is no replied CTS signal from the host computer after the timeout duration the scanner will issue an error indication By setting Host idle Low RTS or Host idle High RTS the scanne...

Страница 16: ...ry Host type Standard 00 OPOS JPOS 01 Flow control None 00 RTS CTS Host idle Low RTS 01 RTS CTS Host idle High RTS 02 XON XOFF 03 ACK NAK 04 Inter character delay 0 ms 00 5 ms 01 10 ms 02 20 ms 03 40...

Страница 17: ...rsion 1 00 EN 17 of 93 Multiple scan setting Single scan setting Option barcode Option Alpha entry 38400 07 57600 08 115200 09 Parity bit None 00 Odd 01 Even 02 Data bit 8 bits 00 7 bits 01 Stop bit O...

Страница 18: ...POS The scanner is connected to a POS terminal which may be necessary to install the OPOS JPOS driver to be compatible with the manufacturer s scanner The OPOS JPOS driver is provided by the scanner m...

Страница 19: ...board for Apple Mac 01 USB virtual COM 02 Simple COM Port Emulation 03 HID for OPOS JPOS 04 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japane...

Страница 20: ...f 93 KP1200 User Manual Version 1 00 EN Multiple scan setting Single scan setting Option barcode Option Alpha entry 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypa...

Страница 21: ...By setting Enable the scanner will start operating if any nearby object has been detected The scanner will stop scanning when there is a successful reading or no code is decoded after the Stand by dur...

Страница 22: ...6 Element amendment If it is enabled the scanner can read the barcode comprised with bars and spaces in different scale Character output restraint Printable character only If this option is selected t...

Страница 23: ...yboard for Apple Mac refer to USB interface If it is enabled the scanner will not start next decode attempt until previous data output is completed Sleep mode If it is enabled the scanner will go to s...

Страница 24: ...ntary 01 Good read on 04 Auto detection Good read on 06 Auto detection Good read off 07 Auto detection sensitivity high 00 low 01 Standby duration 4 seconds 00 8 seconds 01 16 seconds 02 24 seconds 03...

Страница 25: ...lay time for 2D symbol 00 FF16 50 ms 00 FF16 00 08 Double confirm 00 09 00 no 00 09 00 Global max code length for 1D symbol 04 99 04 99 99 Global min code length for 1D symbol 01 99 01 99 04 Global G1...

Страница 26: ...F16 00 Character encoding system ASCII 00 UTF 8 01 Windows 1251 02 Complete data output before next decode attempt Disable 00 Enable 01 Sleep mode Disable 00 Enable 01 Sleep mode delay 1 second 00 5 s...

Страница 27: ...er will beep to indicate a good barcode reading and its beep tone duration is adjustable Beep tone duration This parameter can be adjusted for a good reading upon favorite usage Volume of beeper This...

Страница 28: ...iming pattern When this option is enabled the scanner will project the aiming pattern during the code capture Level of decode illumination This parameter can be adjusted for different level of decode...

Страница 29: ...ways Off 00 Always On 01 Flashing 02 Always On when reading 03 Decode aiming pattern Always Off 00 Always On 01 On before reading 02 On when reading 03 Level of decode illumination Disable decode illu...

Страница 30: ...l centering read By setting Enable the scanner reads only the barcode centered by the aimer in vertical direction However the scanner will read either one of two barcodes which are positioned horizont...

Страница 31: ...w respective 1D symbol setting 00 All 1D OFF 01 2D symbols read Follow respective 2D symbol setting 00 All 2D OFF 01 All 2D ON 02 Only PDF417 ON 03 Only QR code ON 04 Only Data Matrix ON 05 Only MaxiC...

Страница 32: ...the scanner while maintaining the distance of about 15cm between the scan window of the scanner and this paper After a few seconds the scanner will give three short beeps to indicate a successful cal...

Страница 33: ...n group selection Refer to Global insertion group selection of Scan mode some global settings Supplement digits The Supplement digits barcode is the supplemental 2 or 5 characters Format System charac...

Страница 34: ...k digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 44 00 44 00 Supplement digits None 00 2 digits 01 5 d...

Страница 35: ...up selection Refer to Insertion group selection of UPC A Supplement digits Format System character 0 Data digits 6 digits Check digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zer...

Страница 36: ...ck digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 44 00 44 00 Supplement digits None 00 2 digits 01 5...

Страница 37: ...tting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Supplement digits Format System character 1 Data digits 5 digits Check digit Supplement di...

Страница 38: ...Enable 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 44 00 44 00 Supplement digits None 00 2...

Страница 39: ...group selection Refer to Insertion group selection of UPC A Supplement digits Format Data digits 12 digits Check digit Supplement digits 2 or 5 ISBN ISSN conversion The ISBN International Standard Bo...

Страница 40: ...e 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 EAN 13 code ID setting 00 FF16 00 FF16 ASCII A Insert group selection 00 44 00 44 00 Supplement digits...

Страница 41: ...of the numerical value of the data digits Check digit trans By setting Enable check digit will be transmitted Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Inser...

Страница 42: ...Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 C Insert group selection 00 44 00 44 00 Supplement digit...

Страница 43: ...ngth to force the fixed length barcode decoded Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Start End transmission The start...

Страница 44: ...tion Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 99 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00...

Страница 45: ...3 Multiple scan setting Single scan setting Option barcode Option Alpha entry Enable 01 Code 32 Prefix A transmission Disable 00 Enable 01 Trioptic Code 39 read Disable 00 Enable 01 Trioptic Code 39 S...

Страница 46: ...ues of all data digits There are two optional check digit algorithms the specified Uniform Symbol Specification USS and the Optical Product Code Council OPCC Check digit transmission By setting Enable...

Страница 47: ...n barcode Option Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 USS 01 OPCC 02 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 99 Min code length 0...

Страница 48: ...ode 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Multiple scan setting Single scan setting Option barcode Option Alpha ent...

Страница 49: ...Min code length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Multiple scan setting Si...

Страница 50: ...election Refer to Insertion group selection of UPC A Start End type Codabar has four pairs of Start End pattern you may select one pair to match your application Start End transmission Refer to Start...

Страница 51: ...etting Single scan setting Option barcode Option Alpha entry Insert group selection 00 44 00 44 00 Start End type ABCD ABCD 00 abcd abcd 01 ABCD TN E 02 abcd tn e 03 Start End transmission Disable 00...

Страница 52: ...l data digits Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A I...

Страница 53: ...isable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 99 Min code length 00 99 00 99 01 Code ID setting 00 FF16...

Страница 54: ...as the sum module 103 of all data digits Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of Code 39 Code ID setting Refer t...

Страница 55: ...isable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 99 Min code length 00 99 00 99 01 Code ID setting 00 FF16...

Страница 56: ...h Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Multiple scan setting Single scan sett...

Страница 57: ...n code length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Multiple scan setting Sing...

Страница 58: ...s presented as the sum module 11 of all data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method Ma...

Страница 59: ...ption Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 One digit 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 99 Min co...

Страница 60: ...ts i e Mod 10 Mod 10 10 and Mod 10 11 The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Check digit transmission By setting Enable check digit 1 and...

Страница 61: ...entry Read Disable 00 Enable 01 Check digit verification Disable 00 1 digit Mod 10 01 2 digit Mod 10 10 02 2 digit Mod 10 11 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 9...

Страница 62: ...ck digit will be transmitted Max Min code length Refer to Max Min code length ofCode 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection o...

Страница 63: ...Post is 11 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Multiple scan setting Single scan setting Option barcode Option Alpha...

Страница 64: ...ata digits Leading character 5 6 7 8 9 converted to A B C D E By setting leading character 5 6 7 8 9 can be converted to A B C D E Leading character assignment By setting only the barcode with the ass...

Страница 65: ...nly 8 converted to D 05 Only 9 converted to E 06 Leading character assignment Disable 00 Assigned to 0 01 Assigned to 5 A 02 Assigned to 6 B 03 Assigned to 7 C 04 Assigned to 8 D 05 Assigned to 9 E 06...

Страница 66: ...roup selection of UPC A Conversion UCC EAN 128 Refer to Code ID transmission of String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first di...

Страница 67: ...oup selection Refer to Insertion group selection of UPC A Conversion Refer to Conversion of GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option barcode Option Alpha entr...

Страница 68: ...up selection of UPC A Conversion UCC EAN 128 Refer to Code ID transmission of String transmission Cm will be identified as AIM ID Multiple scan setting Single scan setting Option barcode Option Alpha...

Страница 69: ...KP1200 User Manual Version 1 00 EN 69 of 93 3 33 PDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 70: ...70 of 93 KP1200 User Manual Version 1 00 EN 3 34 QR Code Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 71: ...KP1200 User Manual Version 1 00 EN 71 of 93 3 35 Data Matrix Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 72: ...00 EN 3 36 Han Xin Code Note The support for this feature is available with customized firmware version Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option...

Страница 73: ...KP1200 User Manual Version 1 00 EN 73 of 93 3 37 Aztec Code Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 74: ...00 EN 3 38 MicroQR Code Note The support for this feature is available with customized firmware version Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option...

Страница 75: ...ix OS enter is represented as LF 0x0A Prefix Suffix Preamble Postamble string setting They are appended to the data automatically when a barcode is decoded Example Add a symbol of as a prefix for all...

Страница 76: ...barcode of Insert G1 string setting 2 Use the ASCII table to find the value of A 41 B 42 3 Scan 4 1 and 4 2 from the barcode on the last page 4 Scan END barcode 5 Refer to G1 G4 string position Code I...

Страница 77: ...e character can be un defined Repeat of a G5 character setting While G5 is set as a single defined un defined character G5 can also be set to be repeated This setting is ignored when the truncate numb...

Страница 78: ...the barcode data characters The option of FF for this setting is not active while the option of Truncate ending G6 string setting is 00 Single character C1 C2 replacement By setting a defined characte...

Страница 79: ...The maximum number of characters to replace is 11 Example Replace all the A character in a data string with B character replace C with D replace E with F Original code data 1 2 3 A 4 C 5 6 E 7 8 Outpu...

Страница 80: ...cters 00 FF16 None 00 Postamble string setting 0 22 characters 00 FF16 None 00 Insert G1 string setting 0 22 characters 00 FF16 None 00 Insert G2 string setting 0 22 characters 00 FF16 None 00 Insert...

Страница 81: ...times 01 22 Un defined times All FF Truncate ending G6 string setting A un defined character 00 1 22 defined characters 01 7F16 0 30 Repeat of a G6 character setting Once 01 Defined times 01 22 Un de...

Страница 82: ...ymbol In case of the insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placem...

Страница 83: ...transmission The length of code data string can be transmitted before the code data when Enable is selected Case conversion The characters within code data or the whole output string can be set in ei...

Страница 84: ...able 01 Code name transmission Disable 00 Enable 01 Preamble transmission Disable 00 Enable 01 Postamble transmission Disable 00 Enable 01 Code ID transmission Disable 00 Proprietary ID 01 AIM ID 02 C...

Страница 85: ...can setting Option barcode Option Alpha entry USB 01 RS 232 02 USB RS 232 03 All non printable character string transmission with string setting Disable 00 Enable 01 Transmit the first N data characte...

Страница 86: ...indow may affect scanning accuracy 1 Do not allow any abrasive material to touch the window 2 Remove any dirt particles with a damp cloth 3 Wipe the window using a tissue moistened with water 4 Do not...

Страница 87: ...nting following barcode is different 2 If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make...

Страница 88: ...7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for...

Страница 89: ...00 User Manual Version 1 00 EN 89 of 93 7 Test barcode UPC A UPC E UPC E1 Default setting Disable EAN 13 ISBN ISSN EAN 8 Code 39 Interleaved 2 of 5 Industrial 2 of 5 Default setting Disable Matrix 2 o...

Страница 90: ...0 EN Codabar Code 128 UCC EAN 128 ISBT 128 Code 93 Code 11 Default setting Disable MSI Plessey Default setting Disable UK Plessey Default setting Disable China Post GS1 DataBar GS1 DataBar Truncated G...

Страница 91: ...93 PDF417 12 890ab xyz QR code 1234567890ABCD XYZ Data Matrix 123890abc mdo Aztec Code Default setting Disable 12345678901234567890 Han Xin Code Default setting Disable 1234567890Hanxin Micro QR Code...

Страница 92: ...ault parameters list firmware version WARNING Default value initialization If you wish to return the scanner to all the factory default settings scan the barcode above Firmware version list If you wis...

Страница 93: ...KP1200 User Manual Version 1 00 EN 93 of 93 9 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...

Отзывы: