Manual
Article No.: 843273
6
Importer
Auf der Hub 2
Tel.: +49 7248 / 92 71 500
Web: www.deko-light.com
D-76307 Karlsbad
Fax: +49 7248 / 92 71 550
Mail: [email protected]
7. Operation
DMX Adressing
DMX addresses can be entered by using the DIP switches 1-9.
Each DIP switch is set for a binary value.
8. Fundamental information
To derive the heat, we recommend the installation to allow sufficient space for the air to circulate
and the driver will not be overheated. Make sure that all connections are tight. The signal line
should be as far away from the power line (230V).
DIP Switches binär Value
1
1
2
2
3
4
4
8
5
16
6
32
7
64
8
128
9
256
10
3 / 4 CH
Examples:
DIP Switch 1 & 3
= 1 + 4
= Adress 5
DIP Switch 2 & 4
= 2 + 8
= Adress 10
DIP Switch 1 & 2 & 4 & 5
= 1 + 2 + 8 + 16
= Adress 27
A DMX value (address) will be entered by linking (add) the
various dip switches. They add up to the desired value set