KAP Medical ALT-AIRE K-1oem Скачать руководство пользователя страница 1

                                                                                                                                

                                                                                                          

 

 

 

 OPERATING INSTRUCTIONS 

K-1 & K-2 ELITE & OEM SERIES 

 

 

K-1 ELITE ~ DERMA-KARE™ 

 

DIGITAL ALTERNATING PRESSURE SYSTEM 

 

 

K-1oem ~ ALT-AIRE™ 

 

ALTERNATING PRESSURE SYSTEM 

 

 

K-2 ELITE ~ KARE-ZONE™ 

 

DIGITAL ALTERNATING PRESSURE WITH ON-DEMAND LOW AIR LOSS SYSTEM 

 

 

K-2oem ~ ALT-AIRE+™ 

 

ALTERNATING PRESSURE WITH ON-DEMAND LOW AIR LOSS SYSTEM 

 

US & INTERNATIONAL PATENTS PENDING 

Please read this manual before using this product. Do not discard.  

 

Save for future reference.

 

 

This manual MUST be given to the user of this product. 

Содержание ALT-AIRE K-1oem

Страница 1: ...E SYSTEM K 2 ELITE KARE ZONE DIGITAL ALTERNATING PRESSURE WITH ON DEMAND LOW AIR LOSS SYSTEM K 2oem ALT AIRE ALTERNATING PRESSURE WITH ON DEMAND LOW AIR LOSS SYSTEM US INTERNATIONAL PATENTS PENDING Please read this manual before using this product Do not discard Save for future reference This manual MUST be given to the user of this product ...

Страница 2: ...vice 1 866 KAP MED 1 866 527 6331 Technical Support Service 1 951 340 4366 Email sales kapmedical com service kapmedical com www kapmedical com FDA Registered Company California FDA Registered Company Medicare Coded SADMERC Health Canada Medical Device Licensed ISO 13485 Certified Company Medical Device Electrical Safety Tested SGS Fire Safety Tested MADE IN USA ...

Страница 3: ...Rail Entrapment Risk Notification 9 Unit Overview 11 Explanation of Symbols Used 13 Mattress Overview 15 Unpacking the System 16 Mattress System Set Up 17 Operating Instructions 18 CPR Function 23 Patient Transportation 24 Cleaning Procedure 25 Care and Storage 26 Troubleshooting Guide 27 Preventive Maintenance 27 Accessories 27 Control Unit Calibration and Settings 28 Warranty Information 29 Quic...

Страница 4: ...upport combustion Failure to observe this warning can result in severe fire property damage and cause injury or death Entrapment may occur Patient entrapment with bed side rails and mattress may cause injury or death Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment Follow the manufacturer s instructions and monitor patient frequently Proper patient assessment and mon...

Страница 5: ...t harmful interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Intended Use The KAP MEDICAL Air Therapy Systems are intended to be used for the prevention and treatment of decubitus ulcers NOTE INFORMATION CONTAINED IN THIS OPER...

Страница 6: ...52 LPM Support Surface Inflation Time 5 15 Minutes Patient Comfort Pressures Alternating Pressure Soft Pressure 6 5 mmHg K 1 K 2 Firm Pressure 32 5 mmHg K 1 31 5 mmHg K 2 of high AP pressure setting A P Time 1 Minute 99 Minutes A P Low Pressure 0 80 K 1 Elite 0 75 K 2 Elite Patient Comfort Pressures Alternating Pressure Soft Pressure 7 5 mmHg K 1oem K 2oem Firm Pressure 32 5 mmHg A P Time 5 10 15 ...

Страница 7: ...in height replacement mattresses available along with 3 or 5 mattress overlays Packaging 1 piece per box Patented Low Air Loss top sheet on K 2 and k 2oem models only Optional mattress with Kevlar lined fire barrier top sheet and mattress base available Environmental Specifications Operating Conditions Ambient Temperature 40 104 F 10 40 C Relative Humidity 30 75 Non Condensing Atmospheric Pressure...

Страница 8: ...s California117 Optional California TB 106 TB 129 16 CFR 1632 16 CFR 1633 BS 6607 CRIB 5 BS 597 1 BS 597 2 compliant mattresses lined with Kevlar fire barrier available Kevlar lining based on flammability standard All Foam Aire TM mattresses are TB129 1632 1633 compliant FDA Registration FDA registered company as a manufacturer and as a contract manufacturer KAP MEDICAL S quality system meets the ...

Страница 9: ... control unit is not blocked and kept away from any heat sources or radiators during the operation of the unit Care should be taken such that the power cord of the control unit is not pinched or has any objects placed on it Make certain it is not located where it can be stepped on or tripped over Do not attempt to service the control unit except as explained in this operating instruction manual Co...

Страница 10: ...y patient is unique Only the patient s medical care provider is familiar with the patient s unique medical condition and needs Only the patient s medical care provider and or the dealer from whom you obtained this equipment upon proper assessment of the patient s medical condition and needs can evaluate whether this equipment is appropriate for use by any particular patient and assist the patient ...

Страница 11: ...aces TSS which support the patient on an air mattress or specialized foam layer may present an increased risk of entrapment for some patients The benefit of TSS product use must be weighed against the potential increased risk of entrapment The risk judgment must be performed by a medical professional The U S Food and Drug Administration in partnership with the U S Department of Veterans Affairs He...

Страница 12: ...e Thermoplastic 94V 0 fire retardant enclosure houses a compressor main PCB display panel a short circuit over voltage protection with single dual fuse a quick connection and disconnection CPR deflation coupling connector R with flow ports with RTPM real time pressure monitoring technology sensors and a 10 to 14 305cm to 427 cm long detachable 16 AWG hospital grade power cord Q Unit Label Location...

Страница 13: ...es Owner s Manual Page 12 Refer to the Explanation of Symbols Used chart on page 13 for a cross reference of Display Key descriptions Unit Display Labels K 1 DERMA KARE K 1oem ALT AIRE K 2 KARE ZONE K 2oem ALT AIRE ...

Страница 14: ... STATIC T or Selects Static Therapy mode LOW AIR LOSS Y or or Activates Low Air Loss mode ALTERNATING PRESSURE AP or or Selects A P mode AP TIME TT or Selects AP cycle time FOWLER U or Fowler Mode The pressure will increase to prevent the patient from bottoming out MAX Inflate W or or Inflates mattress rapidly 30 minute timer POWER FAIL PF In the event of power failure or if the hose is disconnect...

Страница 15: ...cluded with each model SYMBOL EXPLANATION No Sharp Objects Low Heat Setting Do Not Dry Clean Do Not Bleach No Open Flames Normal Cycle Do Not Iron Latex Free Bolstered Mattress Even Bolstered Mattress Bolster Deflate Mattress Deflate Air Pad Deflate CPR Deflate SN Serial Number Date of Manufacture Manufacturer ...

Страница 16: ...s top sheet has a special multi chambered air distribution layers which administers low air loss relief directly underneath the patient Top layer made out of urethane coated 70 Denier nylon or Dartex or 2 or 4 way stretch low friction low shear force producing breathable liquid resistant and vapor permeable middle layer made out of special spacer material and bottom layer is a water resistant nylo...

Страница 17: ...r of moving bed components before placing a patient on the bed and that the mattress system is fully inflated Operate all bed frame motorized functions through their full range of motion to be certain that there is no pulling interference or pinching Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment See Figure 1 Page 16 UNPACKING THE SYSTEM Note When opening the large...

Страница 18: ...t mattress system care should be taken such that the mattress is placed directly on the bed frame Figure 1 B Page 16 Unroll the Replacement Mattress and place it on the bed frame BF There are ten nylon black straps with buckles F two straps at the head of the mattress two on the foot of the mattress and three on each side of the mattress Loop each strap around the bed deck and secure using the buc...

Страница 19: ...em initialization routine for a few seconds Once the routine is completed the display D will read KAP MEDICAL STANDBY K 1oem K 2oem During initial power up when power cord Q is plugged into the power source X the control unit will have an illuminated amber light indicating that the unit is in Standby mode POWER SB Press Power key the amber Standby LED will turn off and the green LED turns on The c...

Страница 20: ...patient s body There should be a minimum of 3 to 4 finger width clearance between the bottom of the patient and the safety foam base on an overlay there is no safety foam base Repeat this procedure until the desired patient comfort pressure is achieved ALTERNATING PRESSURE AP or or To set Alternating Pressure AP mode Press the AP AP key to activate AP mode in K 1 Elite and K 2 Elite models Press t...

Страница 21: ...e even numbered air cushions deflate to the set percentage of the patient comfort high pressure in the first half of the AP cycle and vice versa for the second half of the cycle and continue back and forth PULSE N WAVE K 2 Elite model This mode is selected by pressing the M Mode key until PULSE is displayed on the screen During Pulse mode the pressure in each air cell will be decreased by 50 for 5...

Страница 22: ...r is factory programmed to a 35 or 45 angle depending on the customer s requirements It uses a 3 6V Lithium battery that can be replaced using KAP Medical part number 100622 S When the battery is first inserted into the battery holder the LED will flash a green light indicating the angle that the Auto Fowler was set for Three 3 flashes indicates a 35 Auto Fowler Four 4 flashes indicates a 45 Auto ...

Страница 23: ... Cushion K 140 OPTIONAL SAC Optional foot support air cushion can be used to support patient s feet and to provide zero interface pressures in the heel area FOAM AIRE MATTRESS AS A NON POWERED MATTRESS Foam Aire mattress can be used as a non powered mattress without the control unit Before using the mattress connect the control unit to the mattress and inflate the mattress by setting the control u...

Страница 24: ...e mattress for a CPR procedure pull the hose V from the control unit connector press connector latches then pull connector If the mattress is equipped with bolsters and or air pad unplug the corresponding deflate plug located at the foot end of the mattress b If the RED CPR VALVE is present on the mattress overlay twist the CPR valve to the open position CPR valve is located at the foot end of the...

Страница 25: ...l unit flange connector PLEASE NOTE Before using the mattress please make sure that the mattress deflate connector is re connected back into the mattress deflate valve PATIENT TRANSPORTATION 1 Air Mattress a To transport a patient without removing the patient off the bed turn off the control unit disconnect the power cord from the power source and roll it up on the control unit securely b The matt...

Страница 26: ...pray the exterior of the top and the bottom enclosures power cord and the cord plug with the prepared disinfectant detergent solution Using a damp cloth wipe down the sprayed surface cleanly Note Do not spray excess amount of solution on the control unit 6 Once the control unit is clean wipe the unit power cord cord receptacle and the cord plug with a clean dry cloth 7 Place the control unit to dr...

Страница 27: ...Note The Foam Aire mattresses have a Kevlar fire retardant sleeve sock barrier inside the cover Care should be taken if removing the cover for cleaning Before attempting to clean the mattress remove the bedding from the mattress The mattress cover top sheet can be cleaned following the steps below 1 Wear eye goggles and protective gloves before starting the cleaning procedure 2 Follow steps 2 thro...

Страница 28: ...to power source 3 Check power source has power and turn it ON 4 Wait till the power source has power 5 Send control unit back to factory for repair C Control Unit not responding 1 Unit locks up 1 Unplug power cord from control unit wait 15 minutes and plug cord back to reset the control unit PREVENTIVE MAINTENANCE It is important to periodically test the control unit to verify its functionality If...

Страница 29: ...pressure setting or 7 75 mmHg of high comfort pressure setting Use the Soft Firm keys to toggle between AP Low modes To end routine and accept setting press Power key Routine will auto time out K 2 ELITE K 2 OEM SERIES K 2 ELITE K 2oem Calibration Control Unit must be in Stand By mode and the mattress hose disconnected Press and hold AP LAL keys until unit beeps Approx 3 seconds Unit will display ...

Страница 30: ...DICAL be liable for any loss direct indirect incidental or special damages arising out of or in connection with the use of this product The control unit warranty does not cover normal maintenance such as cleaning periodic electrical tests performance tests and updating of equipment or parts thereof This warranty shall be void and not apply if the control unit including any of its parts is modified...

Страница 31: ...K 1 K 2 Series Owner s Manual Page 30 NOTES Unit S N __________________________________ Mattress S N _______________________________ Auto Fowler S N ____________________________ ...

Страница 32: ...onnected securely to the control unit Plug the hospital grade power cord provided with the unit into a three pronged hospital socket The display will read KAP MEDICAL STAND BY Press POWER key SB to green light position and then press MAX Inflate W The compressor will come on and inflate the mattress Using the SOFT FIRM keys K set patient comfort pressure settings Screen will show patient comfort s...

Страница 33: ...ttress hose assembly is connected securely to the control unit Plug the hospital grade power cord provided with the unit into a three pronged hospital socket The amber light will illuminate Press POWER key SB to green light position and then press MAX Inflate W The compressor will come on and inflate the mattress Using the SOFT FIRM keys K set patient comfort pressure settings 7 segment display wi...

Страница 34: ...to set the patients height and weight Patient comfort settings will be automatic when done with settings Adjust the SOFT FIRM knob K to bypass automatic patient comfort pressure settings Actual mattress pressures in mmHg millimeters of mercury will be displayed on the control unit display For ALTERNATING PRESSURE therapy press the A P key to start A P mode The display will read A P time 10 00 minu...

Страница 35: ...de power cord provided with the unit into a three pronged hospital socket The amber light will illuminate Press POWER key SB to green light position and then press Select key S until MAX Inflate LED W lights up The compressor will come on and quickly inflate the mattress Using the SOFT FIRM keys K set patient comfort pressure settings 7 segment display will show patient comfort settings from 0 low...