background image

 

 

Tel.: 1 (450) 444 2030 

 Toll Free: 1 888 222-1560 

 Fax: 1 (450) 444 2029 

 Internet: www.kantech.com 

DN1247-0404

 

Copyright 

 2004 Kantech Systems. All rights reserved 

 Specifications may change without notice. 

Kantech Systems 

KT-PC4216

Output Module

/

 

1. Introduction 

The 

KT-PC4216

 is an open collector to 12 VDC 16 zones output module. It can 

be used for elevator access control (may require additional hardware). 

2. Specifications 

• 

16 outputs low current module, 12V, 50mA max. each, power drawn from 
Combus (since Combus can handle a maximum of 500mA, a KT-PC4204 
module in “repower” mode can be used to increase the current of the 
Combus of 1 Amp) 

• 

Connects to KT-300 via 4-wire Combus 

• 

Nominal current draw of 15mA (from Combus) 

• 

Tamper contact input 

• 

Can be used for elevator access control 

3. 

Installing the KT-PC4216 

3.1. Unpacking 

The 

KT-PC4216

 package should include the following parts/items: 

• 

One (1) KT-PC4216 circuit board 

• 

Four (4) plastic standoffs 

• 

One (1) installation instructions sheet 

3.2. Mounting  

The 

KT-PC4216

 should be located inside a compatible cabinet (Kantech part no. 

KT-4051CAB), mounted in a dry, secure location. Preferably, it should be placed 
at a convenient distance from the connected devices. 

Perform the following steps to mount the unit: 

1. 

Press the four (4) plastic standoffs through the mounting holes at back of 
the cabinet,  

2. 

Secure the cabinet to the wall in the desired location. Use appropriate wall 
anchors when securing the cabinet to drywall, plaster, concrete, brick or 
other surfaces, 

3. 

Press the circuit board into the plastic standoffs to secure the module to the 
cabinet. 

Once the unit is mounted, wiring may be started. 

3.3.  Installation and Wiring 

Before beginning to wire the unit, ensure that all power (AC transformer and 
battery) is disconnected from the controller. 

 

Perform the following

 steps to complete wiring: 

1. 

Connect the four Combus wires to the KT-PC4216. Connect the red, black, 

yellow and green Combus wires to the RED, BLK, YEL and GRN 

terminals, respectively.  

2. 

Complete all output wiring as illustrated below: 

Note

: Current is drawn from the combus

  

 

Note

: May require a KT-PC4204 power supply module if drawing too much 

current from the Combus. 

 

3. 

Connect the external tamper switch, if used. 

Consult the wiring diagrams for further information. 

3.4. Applying Power 

After all wiring is completed, apply power to the KT-300 controller. Connect the 

battery leads to the battery, then connect the AC transformer.   

Note

: Do not connect the power until all wiring is complete. 

 

Отзывы: