11
11
11
11
11----4 Adjusting the movable knife left to right
4 Adjusting the movable knife left to right
4 Adjusting the movable knife left to right
4 Adjusting the movable knife left to right
Movable knife C should pass clearance B between
spreader A and the left needle. Loosen screws H on
bracket G. Adjust movable knife C while checking it
does not touch spreader A or the left needle.
11
11
11
11----5 Adjusting the movable knife front to back
5 Adjusting the movable knife front to back
5 Adjusting the movable knife front to back
5 Adjusting the movable knife front to back
The movable knife should hook the top cover thread
when the movable knife returns home.
There should be a clearance of approximately 1mm
between hook point D of movable knife C and the top
cover thread. Adjustment is made by loosening
screws J on movable knife mounting base I.
11
11
11
11----6 Adjusting the height of the movable knife
6 Adjusting the height of the movable knife
6 Adjusting the height of the movable knife
6 Adjusting the height of the movable knife
When the movable knife is at the bottom of its travel,
hook point X of the movable knife should be aligned
with the top surface of the spreader.
Adjustment is made by moving stopper B (see the
illustration on the previous page).
Then tighten screws F when bracket E is in the lowest
position.
< Note >
The following adjustments should be made manually with the fabric under the
presser foot when the needle is at the top of its stroke.
< Note >
Turn off the power first and then adjust by hand with
the fabric under the presser foot.