9
5555----7 Changing the amount of the looper front
7 Changing the amount of the looper front
7 Changing the amount of the looper front
7 Changing the amount of the looper front----to
to
to
to----back movement
back movement
back movement
back movement
The clearance between the point of the left needle
and the back side of the looper when the looper
moves to the right from the extreme left end of its
travel should be 0.3~0.6mm (The needle is pressed
to the back). The distance between the point of the
left needle and the center of the looper's eye on the
back side of the looper should be 3~3.5mm.
The amount of the looper front-to-back movement is
factory-set properly for needle count #14 (Nm90).
If you use needle counts #11 (Nm75), adjust the
amount as required.
Remove the inside cover.
Loosen nut B while holding screw A for the looper
front-to-back adjusting pin with a screwdriver.
Then move the front-to-back rod front or back.
To increase the amount, move alignment mark D on
the front-to-back rod to the front from mark C on the
looper bar guide.
To decrease the amount, move mark D to the back.
Adjust according to the needle count.
< Note >
If you change the amount of the looper front-to-back movement, the clearance between
the point of the left needle and the back side of the looper when the looper moves to the
right from the extreme left end of its travel should be 0.3~0.6mm.