ANEMOMASTER   

MODEL 6036 

 

Data Acquisition Software (6036-41) 

PC-LINK Software (6036-45) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

02001 

1901 

Operation Manual

 

Содержание Anemomaster 6036

Страница 1: ...qw ANEMOMASTER MODEL 6036 Data Acquisition Software 6036 41 PC LINK Software 6036 45 02001 1901 Operation Manual ...

Страница 2: ...tware 2 Right click the icon of the software and click Properties or click Properties of the desktop icon 3 Click the Compatibility tab in the Software Properties window 4 Check Run this program as an administrator under Privilege Level 5 Click OK to close the window Note If you do not follow the above procedure the software may abort with a runtime error when reading or printing data ...

Страница 3: ... one of the folders in Program Files Program Files x86 for 64 bit Click Compatibility files in Windows Explorer to display the data If you cannot perform this operation or Compatibility files does not appear you need to save the data in a folder such as My Documents which users can read and write to ...

Страница 4: ...rement 8 4 2 1 Starting a Measurement 8 4 2 2 Stopping a Measurement 9 4 2 3 Displaying Measurement Data 10 4 2 4 Air Velocity Graph Setting 10 4 2 5 Data Save 11 4 3 Example of Saved Data 12 4 4 Display Language 12 4 5 Software Information 12 5 PC LINK Software 6036 42 13 5 1 Software Startup 13 5 2 Data Acquisition 14 5 2 1 Acquiring Data from Anemomaster 14 5 2 2 Viewing Data Saved on the Compu...

Страница 5: ...MOMASTER MODEL 6036 is used to download stored measurements from the Anemomaster to a computer These downloaded measurement files are stored in csv format and can be viewed using a compatible program such as MS Excel 1 2 Software Operating Requirements OS Microsoft Windows 7 SP1 or higher Microsoft Windows 8 8 1 Microsoft Windows 10 Communication USB Port 1Port NOTE 1 Any unauthorized duplication ...

Страница 6: ...w version 2 Insert the CD ROM into the computer Then double click the Setup exe 3 The User Account Control dialogue will pop up Click Yes 4 Welcome screen is displayed To start the setup program click Next 5 You can select what folder to install the software The default directory is c program files Anemomaster Model 6036 Software To change the installation folder click Browse button and select the...

Страница 7: ...3 Data Acquisition Software S603 60 3 7 You are now ready to install the software Click Next to start installation 8 When the installation is complete as shown in the right figure click Finish ...

Страница 8: ...re Wizard window will be displayed Install the device driver following the procedure below To install the device driver be sure to insert the product CD ROM into the CD ROM driver 3 1 1 Windows 7 8 8 1 10 1 Please wait while Installing device driver software message is being displayed in the lower right of the screen 2 In a short time Device drive software was not successfully installed message wi...

Страница 9: ... in Other Device and right click it Highlight and click on Update Driver Software in the menu 6 Click Browse my computer for driver software 7 Type the name of the CD ROM drive in Search for driver software in this location box and click Next 8 In the resulting Windows Security dialogue click Install this driver software anyway to start the installation of the driver software ...

Страница 10: ...3 Data Acquisition Software S603 60 6 9 When the installation is complete as shown in the right figure click Close ...

Страница 11: ...ware Startup To start up the Anemomaster Data Acquisition Software click start All Programs Kanomax Anemomaster Model 6036 Data Acquisition Software Startup Window Operation Status Measurement Information Flow Rate Graph Air Velocity Data Table Air Velocity Graph Flow Rate Data Table ...

Страница 12: ...eter Setting dialog box will be displayed Configure each setting for a measurement 3 To start a measurement based on the selected measurement setting click Measurement a Measuring Parameter Setting Dialog Box 1 600 sec Sampling Time 1 65500 times Number of Sampling Duct Shape Sampling Method 0 2550 mm 0 255 inch Set width height or diameter for the duct to be used A Serial No of the Connected Inst...

Страница 13: ...ng a Measurement 1 Click Measurement Measurement Stop from the menu bar Or click button on the tool bar or press F5 key 2 A confirmation window will ask you if you want to stop a measurement 3 To stop a measurement click Yes B B Screen while measuring ...

Страница 14: ...easurement data cannot be displayed in the above format 4 2 4 Air Velocity Graph Setting 1 Click View Wind Speed Graph Parameter Edit from the menu bar Or click button on the tool bar or press F6 key 2 Graph Parameter Edit window will be displayed 3 Set the X axis horizontal axis that indicates time a unit select one from sec min hour day Example of Measurement Data Display Data mark line Graph Pa...

Страница 15: ...setting scale will be set automatically 4 2 5 Data Save 1 To save a measurement data click File Save Or click button on the tool bar or press F3 key 2 Save As window will be displayed 3 Enter a file name a 4 Select the format CSV or TXT in which to save the file b 5 Click Save to save data c If you do not want to save data click Cancel d Save As window a b c d ...

Страница 16: ...heric pressure compensation Manual 3 Atmospheric pressure compensation Error 4 4 Display Language Display language can be selected from English or Japanese from the View menu 4 5 Software Information To check the name version and copyright information of the software click Help About The below window will be displayed Software Name Version and Copyright Information window CSV format TXT format ...

Страница 17: ...13 5 PC LINK Software 6036 42 5 1 Software Startup To start up the Anemomaster Data Acquisition Software click start All Programs Kanomax Anemomaster Model 6036 PC LINK Software Startup Window Data List Directory Saved File List ...

Страница 18: ...ion manual for instructions on storing measurements 1 Select the drive a and directory b where the acquired data will be saved 2 Enter a file name for the data to be acquired c 3 Click Read Data to begin acquiring data from Anemomaster The saved acquired data will be listed in the data list e 5 2 2 Viewing Data Saved on the Computer 1 Select the drive a and directory b where the data acquired from...

Страница 19: ...nsation Error 5 4 Error Message 1 File Name Error 2 Drive Error 3 Communication Error Before acquiring data you need to enter a file name When you try to acquire data without entering a file name this message will be displayed When the selected drive cannot be access this message will be displayed When this communication error occurs check if the cable is connected properly and status of the instr...

Страница 20: ...TER MODEL 6035 6036 P 21 and set the Baud rate of the instrument to 19200bps Confirm the communication settings Make sure that the computer is connected to the Anemomaster with a communication cable After making proper connection close the software and reboot it If you require additional technical support please contact your local distributor or our service center ...

Страница 21: ... com E mail info kanomax usa com Japan Asia KANOMAX JAPAN INC 2 1 Shimizu Suita City Osaka 565 0805 Japan TEL 81 6 6877 0183 FAX 81 6 6877 5570 URL http www kanomax co jp E mail sales kanomax co jp China Shenyang Kano Scientific Instrument Co Ltd No 12 4 Jia Wencui Road Heping District Shenyang City PRC TEL 86 24 23845309 FAX 86 24 23898417 URL http www kanomax com cn E mail sales kanomax com cn ...