background image

 
 
 

KANE255 

Combustion Analyser 

 

 
Stock No:  19463     July 2014 

 
© Kane International Ltd 

Содержание 255

Страница 1: ...KANE255 Combustion Analyser Stock No 19463 July 2014 Kane International Ltd...

Страница 2: ...USING THE FOUR FUNCTION BUTTONS 9 11 7 USING BUTTONS 11 8 USING THE ROTARY DIAL STARTING FROM MENU 12 13 9 MEASURING FLUE GASES 14 18 10 EXAMPLE PRINTOUTS IN AMBIENT AIR 19 20 11 WHEN YOU FINISH USIN...

Страница 3: ...Page 3 15 ELECTROMAGNETIC COMPATIBILITY 29 16 END OF LIFE DISPOSAL 29 APPENDIX 1 MAIN PARAMETERS 30 31 APPENDIX 2 SYMBOLS USED ON THE DISPLAY 32 PRODUCT REGISTRATION 33 34...

Страница 4: ...a time and all data can be printed via an optional infrared printer The printed data can be live data frozen data or stored data 20 sets of tests can be stored Two lines of 16 characters can be added...

Страница 5: ...Page 5 ANALYSER LAYOUT FEATURES...

Страница 6: ...Page 6...

Страница 7: ...are fitted with the correct battery polarity Replace the battery cover and the protective rubber cover Switch the analyser on and check that the analyser s date and time are correct To reset the date...

Страница 8: ...the analyser s flue gas inlet and connect the flue probe s temperature connector to the T1 socket check the plug s orientation is correct otherwise incorrect temperature measurements will occur After...

Страница 9: ...ument is also exposed to a known gas mixture but is allowed to settle to a steady figure and the reading adjusted to the stated gas concentration of the test gas 6 USING THE FOUR FUNCTION BUTTONS Swit...

Страница 10: ...ze function Press the backlight button for 2 seconds to switch on the analysers display backlight Press the backlight button for 2 seconds to disable the backlight NOTE Use of the backlight significan...

Страница 11: ...itched on ready to accept data and the infa red receiver is inline with the emitter of the analyser on top of the analyser Storing Data Press and hold the SEND PRINT button for approximately 2 seconds...

Страница 12: ...t 6 Header 2 lines each of up to 16 characters that appear on the printout Use ENTER and UP DOWN 7 Gross or Net or Condensing Boiler Furnace efficiency 8 ppm or mg m3 9 Report 10 Printing select the P...

Страница 13: ...n EFFg or EFFc as selected by the user CO2 CO Displays Carbon Dioxide in and Carbon Monoxide in ppm RATIO Displays the CO CO2 ratio and the selected fuel type TEMP Displays the flue Tf and inlet Ti te...

Страница 14: ...probe s maximum temperature Do not exceed the meter s internal temperature operating range Do not put the meter on a hot surface Do not exceed the water trap s levels Do not let the meter s particle f...

Страница 15: ...ges of 2 lines and can be set by the user They remain the AUX parameters until changed by the user Press the SEND PRINT button for 1 second to print the full combustion test Press and hold the SEND PR...

Страница 16: ...ton for 1 second to print the full combustion test Press and hold the SEND PRINT button for approximately 2 seconds to store the combustion test in the memory Press the BACKLIGHT key for one second to...

Страница 17: ...ately 2 seconds to store the combustion test in the memory Press the BACKLIGHT key for one second to freeze the readings before printing Fuel display SET FUEL Set the fuel source NATU GAS Fuel source...

Страница 18: ...n for 1 second to print the full combustion test Press and hold the SEND PRINT button for approximately 2 seconds to store the combustion test in the memory Press the BACKLIGHT key for one second to f...

Страница 19: ...OUR COMPANY NAME PHONE NUMBER HERE SERIAL NO 000000000 DATE 01 07 14 TIME 12 00 08 COMBUSTION FUEL NAT GAS O2 20 9 CO2 00 0 CO ppm 000 CO ppm n 000 02 REF 00 0 C a l d u e o n 0 1 0 7 1 5 CO CO2 0 000...

Страница 20: ...V 1 00B YOUR COMPANY NAME PHONE NUMBER HERE SERIAL NO 000000000 LOG 001 DATE 01 07 14 TIME 12 00 08 COMBUSTION FUEL NAT GAS O2 20 9 CO2 00 0 CO ppm 000 CO ppm n 000 02 REF 00 0 C a l d u e o n 0 1 0 7...

Страница 21: ...WILL BE HOT and let it cool Do not put the probe in water which will be sucked into the meter damaging its pump and sensors When the meter s readings return to ambient levels switch it off The meter c...

Страница 22: ...lyser not running on mains adapter Batteries exhausted AC charger not giving correct output Fuse blown in charger plug Analyser does not respond to flue gas Particle filter blocked Probe or tubing blo...

Страница 23: ...quire more frequent re certification Kane International has service facilities at Atherton near Manchester Tel 01942 873434 the primary service centre for UK customers and at Welwyn Garden City in Her...

Страница 24: ...ertfordshire AL7 1JG Sending your analyser Once the analyser has been securely packed then your package is ready for shipment back to Kane If you do not have an account with a courier company you can...

Страница 25: ...tment Kane International Ltd Gibfield Park Avenue Atherton Manchester M46 0SY Southern Service Department Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Northe...

Страница 26: ...Page 26...

Страница 27: ...Temperature External sensor 0 600 C 0 1 C 2 C 0 3 reading Flue Gas Measurement Oxygen 2 0 21 0 1 0 3 Carbon monoxide 1 0 20ppm 21 2 000ppm nom 4 000ppm max for 15 mins 1ppm 3ppm 5 reading Carbon Diox...

Страница 28: ...h 200mm 7 8 long stainless steel shaft type K thermocouple and 3m 6ft long neoprene hose Ambient Operating Range 0 C to 40 C 32 104 F 10 to 90 RH non condensing Storage Capacity 20 sets of test result...

Страница 29: ...rence or switch off if possible the offending equipment during your test At the time of writing this manual July 2014 Kane International Ltd are not aware of any field based situation where such inter...

Страница 30: ...or INLET temperature from the measured FLUE temperature Displays in either Fahrenheit F or Centigrade C or and will display if the flue probe is not connected COp Carbon Monoxide reading displayed in...

Страница 31: ...lable in When the LO BAT symbol appears this indicates the batteries are at less than 10 of charge and should be replaced readings may be affected if used with low power batteries Warning all stored r...

Страница 32: ...ency TF Flue temperature TI Inlet temperature T Nett temperature EfG Gross efficiency EfN Nett efficiency EfC Condensing efficiency PO Pump off O Calculated oxygen greater than 18 so calculation is di...

Страница 33: ...b Title Company Name Company Address 1 Address 2 Town City County Postcode Country Phone Number Fax Number Mobile Number Email Address Product Details Note Proof of Purchase may be required for warran...

Страница 34: ...al Recommendation Internet Search Exhibition Other Which do you read most often Often Sometimes Hardly Ever Registered Gas Engineer Gas Installer P H P I P H A M News Heating Ventilating Plumbing Heat...

Страница 35: ...Page 35...

Страница 36: ...r buying this analyser Before use please register on our website www kane co uk Scan the QR code to go directly to Register your Product on line or complete detach and return the Product Registration...

Отзывы: