6. Description of Parameters
- 146 -
6.5 Control Performance
6.5.1 V/F Curve
■
Linear, Multi-point and Square V/F Curve
Function Code
Parameter Name
Setting Range
Default
F3-00
V/F curve setting
0, 2-9: Linear V/F
1: Multi-point V/F
10: V/F separation
11: Specific V/F separation
0
F3-01
Torque boost
0.0%: automatic torque
boost
0.1% to 30%
Model
dependent
F3-02
Cut-off frequency of torque
boost
0.00 Hz to max. frequency
50.00 Hz
F3-03
Multi-point V/F frequency 1
0.00 Hz to F3-05
0.00 Hz
F3-04
Multi-point V/F voltage 1
0.0% to 100.0%
0.0%
F3-05
Multi-point V/F frequency 2
F3-03 to F3-07
0.00 Hz
F3-06
Multi-point V/F voltage 2
0.0% to 100.0%
0.0%
F3-07
Multi-point V/F frequency 3
F3-05 to rated motor
frequency (F1-04)
0.00 Hz
F3-08
Multi-point V/F voltage 3
0.0% to 100.0%
0.0%
1. General constant-torque linear V/F curve
Figure 6-36 General constant-torque linear V/F curve
Output voltage
F1-02
(Rated voltage)
F3-01
(Torque boost)
F1-01
(Rated frequency)
Output frequency
Output voltage and output frequency change linearly when below rated frequency. It is
applicable to general mechanical drive applications such as conveyors where the load
torque is constant against the speed range.
6
Содержание GT600-4T132G
Страница 1: ...GT600 AC Drive...
Страница 5: ......
Страница 86: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 86 5 2 Setup Flowchart 87...
Страница 87: ......
Страница 100: ...5 Quick Setup 98 5...
Страница 280: ...8 Peripherals and Options 278 8...
Страница 306: ...12 303 11...
Страница 362: ......