background image

User's manual

K&F SONA SUB

KLING & FREITAG GMBH © 2010

Revision 1.2

Page 6 of 21

2.3

Required�signal�processor

When using the SONA SUB, a signal processor is required such as an electronic crossover or the K&F
Controller CD 44.

The signal processor must provide at least the following settings:

1 x high-pass 4th order Butterworth

1 x low-pass 3rd order Butterworth

1 x bell filter

1 x all-pass 1st order (Only if SONA 5 is filtered).

Further information in chapter [Configuration and Connecting Diagram] on page 13 ff.

2.4

Required�mounting�material

For�wall�and�ceiling�mounting:

At least 3 screws (not countersunk) with
a thread diameter of 6 mm,
a head diameter of 10 mm minimum/ 13 mm maximum,
and a head height of 6 mm max.

Rawlplugs or other suitable mounting aids with official technical approval corresponding to the
given requirements.

Содержание SONA SUB

Страница 1: ...B Important Information Please Read Before Use KLING FREITAG GmbH Junkersstra e 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de User s Manual Revison 1 2 Released...

Страница 2: ......

Страница 3: ...ers 7 3 3 Preventing hearing damage 7 3 4 Protecting the Speakers Operating Safety 7 4 Wall and Ceiling Installation 9 5 Correct Ratio between Top and Bass Speakers 12 5 1 Level increase because of ad...

Страница 4: ...his symbol gives instructions for the proper use of the described products Not following these in structions may cause malfunctions or property damage Tip This symbol indicates notes that help you to...

Страница 5: ...on the keyhole princi ple and a fixing hole for horizontal and vertical wall mounting Drilling plan for marking mounting points for wall and ceiling mounting 4 pin Phoenix plug for the corresponding c...

Страница 6: ...Butterworth 1 x low pass 3rd order Butterworth 1 x bell filter 1 x all pass 1st order Only if SONA 5 is filtered Further information in chapter Configuration and Connecting Diagram on page 13 ff 2 4 R...

Страница 7: ...onnections comply with the applicable safety guidelines and that the size and strength are sufficient Ensure that all connections are secured against coming loose and that only authorized statically t...

Страница 8: ...and Connecting Diagram from page 13 Operations with CD 44 Controller For optimal performance and operating safety of the SONA SUB speakers we recommend using the system controller K F CD 44 When oper...

Страница 9: ...illing plan mark the mounting points on the wall or ceiling Caution When mounting always choose at least two of the mounting points as well as the fixation point Choose fasteners that are suitable for...

Страница 10: ...the middle of the speaker 1 Remove the grille by pulling it upwards out of the fastening groove 2 Turn the screws for the keyhole mounting points into the wall 6 7 mm Remove the stopper in the fixing...

Страница 11: ...FREITAG GMBH 2010 Revision 1 2 Page 11 of 21 Re install the grille To install the grille follow the removal instructions in reverse order Then push on the grille so that fold of the grille 1 is secure...

Страница 12: ...l increase which occurs in room edges and room corners can be used The placement in room edges and room corners is also beneficial because of the excitation of more room modes which results in a more...

Страница 13: ...User s manual K F SONA SUB KLING FREITAG GMBH 2010 Revision 1 2 Page 13 of 21 6 Configuration and Connecting Diagram 6 1 Terminal assignment...

Страница 14: ...ONA 5 unfiltered In this mode the polarity of the SONA 5 s input signal must be reversed MONO MIX STEREO Signal Processor Amplifier SONA SUB SONA 5 SONA 5 Amplifier Signal processor settings SONA SUB...

Страница 15: ...ONA 5 Amplifier Signal processor settings CD 44 Settings SONA SUB High pass 32Hz 4th order Butterworth Low pass 80Hz 3rd order Butterworth Bell filter 45Hz 2dB Q 2 All pass 130Hz 1st order Q 0 SONA 5...

Страница 16: ...n down all level controls Only use high quality speaker cables with a sufficient wire gauge The wire gauge depends on the length of the speaker cable Minimum Wire Gauge mm Required Cable Length m 2 x...

Страница 17: ...he system Check to see if the desired signals are applied to the intended speakers and make sure there is no interference Turning down the input level controls may not always prevent distortions in th...

Страница 18: ...ofer with 50mm voice coil Impedance nominal 8 Wiring 4 pin Phoenix connector and Speakon NL4MPR parallel Enclosure Design 12 mm multiplex enclosure structured lacquer in black or white 3 mounting hole...

Страница 19: ...100 1000 Frequency Hz SPL dB 80 100 Frequency response unfiltered Impedance Ohm 0 20 40 Impedance Ohm 30 10 20 100 1000 10000 20000 Frequency Hz SPL dB 60 80 100 Frequency response SONA 5 filtered Sum...

Страница 20: ...REITAG GMBH 2010 Revision 1 2 Page 20 of 21 11 Dimensions 536 0 mm 21 102 175 4 mm 6 906 308 0 mm 12 126 224 5 mm 8 839 449 0 mm 17 677 224 0 mm 8 819 26 0 mm 1 024 43 5 mm 1 713 17 5 mm 0 689 25 5 mm...

Страница 21: ...r with the German registration office EAR Our WEEE registration number is DE64110372 12 1 2 EU Norway Iceland and Liechtenstein It is not allowed to dispose of used electrical equipment as domestic wa...

Отзывы: