Nesis III User’s Manual
8.3
Settings
Figure 68:
Left: Maintenance options. Right: Maintenance warning.
Next check at
specifies engine hours when maintenance check shall be per-
formed.
Warn before
is used to define how many hours before the check the warning
starts to appear on the startup window.
8.3.8
Engine Shut Down
This is special option for the cases, where the engine shall be cooled down
by running on idle before shutting down. When aircraft is below some speed
threshold and the engine RPMs are on idle a large countdown window starts
on the Nesis screen. Once the countdown disappears, it is safe to shut the
engine down.
A long touch on the countdown window closes the window prematurely.
Figure 69a shows the parameters and Figure 69b shows the countdown.
Enable
toggles this function on and off. It is off by default.
RPM threshold
When engine RPMs are above this threshold for a certain
amount of time (exceed time), it is considered that the engine is hot.
When aircraft speed is below the speed threshold and engine RPM is
below this threshold, the countdown starts (only when engine is in hot
mode).