Combo — Manual
3.3
Toggle Illumination Knob
3. Turn the knob to 1013 hPa (29.91 inHg) to complete the proce-
dure. Observe the units and values next to QNH. They changed
from hPa to inHg and vice versa.
3.3
Toggle Illumination Knob
1020
→
1035
→
1013 for hPa or 30
.
12
→
30
.
56
→
29
.
91 for inHg.
This section applies only to instruments without push/rotate knob.
If the external illumination knob does not work – screen does not re-
act on the knob, try the following procedure. This procedure enables
remote illumination knob if it was not enabled or disables illumina-
tion knob, if it was enabled.
1. Turn QNH until it shows 1020 hPa (30.12 inHg) and wait for
about three seconds for a short cyan line to appear on top of
LCD display.
2. Quickly turn the knob to indicate 1035 hPa (30.56 inHg). A
moment later a longer cyan line appears.
3. Turn the knob to 1013 hPa (29.91 inHg) to complete the pro-
cedure.
4. Finally, you need to turn off Indu Combo and then back on in
order to activate the change.
4
Maintenance & Repair
No special maintenance is required.
The instrument has no serviceable parts inside. In the case of mal-
function, it must be sent to factory for a repair.
16
©
Kanardia
2015-2018