background image

wM-Bus 

Dongle SW Tool 

 
 
 
 
 
 

 

 

USER MANUAL 

 
 
 

     

 

 

Kamstrup A/S  
Industrivej 28, Stilling 
8660 Skanderborg 
TEL: 89 93 10 00 
FAX: 89 93 10 01 
[email protected] 
www.kamstrup.dk 

 

 

Содержание wM-Bus Dongle SW Tool

Страница 1: ...wM Bus Dongle SW Tool USER MANUAL Kamstrup A S Industrivej 28 Stilling 8660 Skanderborg TEL 89 93 10 00 FAX 89 93 10 01 info kamstrup dk www kamstrup dk...

Страница 2: ......

Страница 3: ...r x tabs 6 3 3 Dongle tab normally not used for this application 7 3 4 Trace tab 8 4 Software upgrade dongle 9 5 Help menu 10 Appendix A DSMR set up 11 Appendix B OMS T1 meter set up 12 Appendix C Flo...

Страница 4: ......

Страница 5: ...e a Kamstrup heat or water meter or other wireless M Bus meters using C mode communication 5512 1057 GB 12 2011 A1 Figure 1 This Tool is used for setting up the parameters in the dongle to enable it t...

Страница 6: ...Dongle SW Tool Hereafter named Software Tool 1 2 References 5512 1057 GB 12 2011 A1 EN13757 3 Communication systems for meters and remote reading of meters Part 3 Dedicated application layer EN13757 4...

Страница 7: ...n each PC that will be used to communicate with the Dongle Download the software from www kamstrup com and install it on your PC When the installation is completed a Kamstrup icon used for starting th...

Страница 8: ...c see Figure 3 Store the configuration see Figure 3 Note In Figures 2 and 3 all fields marked with red must be filled in The menu tabs of the software are described in the following paragraphs 3 1 Mai...

Страница 9: ...tions Click the Get Statistics button to get information about the last 10 radio communications received by the Dongle Realtime Dongle Data Timestamp Timestamp set by the Dongle when the data is seen...

Страница 10: ...ary M Bus address from 1 to 250 e g the last two digits of the meter s serial number the dongle supports secondary addressing T1 period in seconds Enter a timeout in seconds When the connection betwee...

Страница 11: ...le set up data and display it in this window OPTIONS M Bus enabled Tick this checkbox for enabling wired M Bus Radio enabled Tick this checkbox for enabling set up via wireless M Bus Encryption M Bus...

Страница 12: ...her fields are fixed in the Dongle Remove Dongle Encryption If encrypted M Bus is enabled click this button to remove the encrypted M Bus The option Encrypted M Bus must stay enabled when clicking Rem...

Страница 13: ...UPGRADE button and choose the bin file for the Dongle in the File menu The upgrade starts automatically when selected 5512 1057 GB 12 2011 A1 Figure 6 Do not stop the upgrade when started The upgrade...

Страница 14: ...Help button in the upper right corner or press Ctrl A to open the dialog box wM Bus Dongle SW Tool Here the version of the program is shown and if the USB Tool has been opened the version of this sof...

Страница 15: ...e meter data manually Set the OPTIONS to 0x07 0x0F depending on whether the wired M BUS should be encrypted or not Set Meter install state to 255 Next time the meter sends out an ACCESS DEMAND INSTALL...

Страница 16: ...he checkboxes Meter enabled and Meter data valid Options in HEX 49 Set Meter install state to 1 as there is no installation procedure T1 period in seconds and T2 fraction cannot be set Set IEK and KEY...

Страница 17: ...eter data valid Options in hex 23 If the meter is not installed set the Meter Install state to 255 Next time the meter sends out an ACCESS DEMAND INSTALL STATE Ci 0x06 the Dongle will acknowledge this...

Страница 18: ...re is no installation procedure for Hydrometer Set Meter M BUS address to where you want the meter to respond on the M Bus T1 T2 IEK KEY Rev B barcode and the Option Board data fields are not used War...

Страница 19: ...m will treat the HYD EWT and GWF manufacturers in a special way as they are sent as M Bus signals and not proprietary The ID No Ver and Media will be shown correctly The data can be transferred to the...

Страница 20: ...o OMS T2 protocol and Meter data valid Options in hex 4B Set Meter install state to 1 as there is no installation procedure Set T1 period in seconds to how often the meter is to send out meter data T2...

Страница 21: ...12 1057 GB 12 2011 A1 Figure 14 If TimeDate format F is required to and from the Dongle set up the Dongle as shown in Appendix A DSMR set up However always run unencrypted M Bus i e tick the checkbox...

Страница 22: ......

Отзывы: