MULTICAL® 803
16
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
3
Type overview
MULTICAL® 803 can be ordered in countless combinations as required by the customer. First, select the required
hardware from the type overview and next, select the required software configuration via the configuration number
(config number). Further, certain data is configured under the country code, e.g. the definition of GMT, the primary
M-Bus address as well as the yearly and monthly target dates. Through these selections and configurations,
MULTICAL® 803 can be adjusted for its current task.
The calculator has been configured from the factory and is ready for use. It can, however, be changed/reconfigured
after installation. Reconfiguration can take place from the calculator’s SETUP loop or by using either METERTOOL
HCW or READy. Read more about the SETUP loop in paragraph 6.3 and in the technical description of METERTOOL
HCW (5512-2097).
Type number:
>803-xxxx-xxxx-xxxxxxxx<
The
first
4 digits of the calculator’s type number (803-xxxx-xxxx-
xxxxxxxx) are written on the calculator’s front and cannot be
changed after production.
The 4 digits
in the middle
of the type number (803-xxxx-xxxx-
xxxxxxxx) are not written on the calculator, but are shown in the
display.
The
last
8 digits of the calculator’s type number (803-xxxx-xxxx-
xxxxxxxx) show the 4 communications modules mounted in the
meter. This is not written on the calculator, but can be read from
the display.
Config. number:
>A-B-CCC-DDD-EE-FF-GG-L-M-N-PP-RR-T-VVVV<
The config number is not written on the calculator, but can be
displayed distributed on four readings in TECH loop.
Config 1: >A-B-CCC-DDD<
Flow sensor position-Measuring unit-Resolution-Display
code
Config 2: >EE-FF-GG-L-M<
Tariff-Pulse inputs-Integration mode-Leakage
Config 3: >N-PP-RR-T<
Cold water leakage-Pulse outputs-Data logger profile-
Encryption level
Config 4: >VVVV<
Customer label
Serial number:
>xxxxxxxx/WW/yy<
Consisting of:
8-digit serial number (xxxxxxxx)
2-digit device code for extended availability (WW)
2-digits for production year (yy)
The unique serial number is written on the calculator and cannot
be changed after factory programming.
Data:
During production, MULTICAL® 803 is programmed with a number
of measuring values. See paragraph 3.4 for more details about
these measuring values.