MULTICAL® 302

The coupling must not be pushed further down 
than the first knurling.

No matter where the direct sensor is installed, 
it is very important that you observe the tole-
rances stated in the drawing to the left. If not, 
the O-ring may not provide correct sealing.

 

-

0

0,1

 0 
Ø 9 -0,1

3  Information codes "INFO"

MULTICAL® 302 constantly monitors a number of important functions. If there is a serious error in 
the measuring system or installation, a flashing "INFO" is displayed, and an info code can be read 
by activating the push-button until the measuring unit displays "INFO". The info code is only shown 
if an error has occurred, unless the meter is configured for "static info codes".

Info code Description

Response time

0

No irregularities

 -

1

Supply voltage has been interrupted

 -

4

Temperature sensor T2 outside measuring range

< 32 secs.

8

Temperature sensor T1 outside measuring range 

< 32 secs.

32

Temperature difference has wrong polarity

< 32 secs. and 0.05 m

3

128

Supply voltage too low

< 10 secs.

16

Flow sensor with weak signal or air

< 32 secs.

2

Flow sensor with wrong flow direction

< 32 secs.

If more than one info code appears at a time, the sum of info codes is displayed. If e.g. both 
temperature sensors are outside measuring range, info code 12 (info codes 4+8) is displayed.
Info codes 4 and 8 are set when the temperature falls below 0.00 °C or exceeds 155.00 °C. Info 
codes 4 and 8 are also set for short-circuited and disconnected sensors. 

Note: 

If Info = 4 or 8, the meter's energy calculation and volume accumulation stop.

Содержание MULTICAL 302

Страница 1: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com Installation and User Guide MULTICAL 302...

Страница 2: ...n with minimum vibration and fixed installation with considerable or high vibration level respectively Electromechanical environment E1 housing light industry The meter s signal cables must be drawn w...

Страница 3: ...ting the function 11 8 Communication 11 8 1 Wired M Bus communication 11 8 2 Wireless M Bus communication radio 11 9 Setup Mode 12 9 1 Changing the installation position 13 9 2 Changing the energy uni...

Страница 4: ...One temperature sensor is mounted in the flow sensor from the factory The other sensor ought to be mounted as direct sensor Alternatively both sensors must be mounted in sensor pockets as symmetrical...

Страница 5: ...meter is configured for static info codes Info code Description Response time 0 No irregularities 1 Supply voltage has been interrupted 4 Temperature sensor T2 outside measuring range 32 secs 8 Tempe...

Страница 6: ...ight inlet MULTICAL 302 requires neither straight inlet nor straight outlet to meet the Mea suring Instruments Directive MID 2004 22 EF and EN 1434 2007 A straight inlet section is only necessary in c...

Страница 7: ...may be turned upwards to max 45 and downwards to max 90 compared to the pipe axis 4 5 4 5 9 0 9 0 4 5 4 5 9 0 9 0 Important The meter is most sensitive to air bubbles in the water when the plastic ca...

Страница 8: ...e upper left corner of the meter display an icon indicates if the meter is positioned in the inlet or outlet pipe It is very important to ensure that the meter is correctly positioned as either inlet...

Страница 9: ...broken In case of strong condensation e g cooling applications wall mounting of the calculator is recommended see paragraph 5 2 page 10 8 3 2 4 5 9 8 3 2 4 5 9 In connection with compact mounting the...

Страница 10: ...flow sensor 6 Battery supply MULTICAL 302 is battery supplied with either 1 or 2 A cell batteries Optimal battery lifetime is obtained by keeping the battery temperature below 30 C e g by wall mountin...

Страница 11: ...2 wire cable of 1 5 m The connection is independent of polarity and the M Bus interface is galvanically separated from the rest of the meter M Bus comes with primary secondary and enhanced secondary a...

Страница 12: ...readings of Setup loop are listed below including index numbers Setup loop Loop_3 Index number in display 1 0 Customer number No 1 3 01 2 0 Customer number No 2 3 02 3 0 Date 3 03 4 0 Hour 3 04 5 0 Ta...

Страница 13: ...ave the setting press the button for two seconds until OK appears in the display Outlet If the meter is set to be placed in the outlet the text Outlet is displayed In order to change the setting press...

Страница 14: ...nd conversely the least significant digit disappears if e g you change from kWh with 1 decimal to kWh without decimals See examples below Example 1 GJ with 2 decimals B 2 This is an example of how the...

Страница 15: ...or registers the amount of district heating water flowing through the heating system in m3 cubic metres The temperature sensors placed in inlet and outlet pipes register the cooling i e the difference...

Страница 16: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com User Guide MULTICAL 302 Kamstrup A S 55121351_D2_GB_04 2015...

Отзывы: