9.1 Changing the installation position
The meter is configured for mounting in either flow or return pipe from the factory.
The setup of the meter's installation position can be changed from inlet meter to outlet meter (and
vice versa):
For this purpose, display 3-06 is used. Now, the following is to be carried out:
Inlet
If the meter is set to be placed in the inlet,
the text "inlet" is displayed. In order to change
the setting, press the button for two seconds.
"Setup" is briefly displayed, and then "Inlet"
flashes. Press the button once, and "Outlet" is
displayed. If you want to save the setting, press
the button for two seconds until "OK" appears in
the display.
Outlet
If the meter is set to be placed in the outlet,
the text "Outlet" is displayed. In order to change
the setting, press the button for two seconds.
"Setup" is briefly displayed, and then "Outlet"
flashes. Press the button once, and "Inlet" is
displayed. If you want to save the setting, press
the button for two seconds until "OK" appears in
the display.
Transport state ends when the meter has
registered its first volume accumulation, either
0.01 m
3
(10 L) or 0.001 m
3
(1 L) – determined by
the selected resolution.
When the transport mode has been cancelled,
you only have access to the Setup loop if the
installation seal is broken and the contact
points behind the seal are short-circuited.
Note:
The option Setup has been deselected in certain country codes.