5.2  Wall mounting

The wall fitting makes it possible to mount 
MULTICAL® 302 directly on an even wall. Use 
the fitting as a template to mark and drill two 6 
mm holes in the wall.

 43 

 47 

 47 

 24 

 24 

 8 

 47 

 47 

 24 

 24 

 8 

47

24

24

47

8

43

5.3  Position of calculator

If the flow sensor is mounted in a humid or 
condensing environment, the calculator must 
be placed in a higher position than the flow 
sensor.

6  Battery supply

MULTICAL® 302 is battery-supplied with either 1 or 2 A-cell batteries. Optimal battery lifetime is 
obtained by keeping the battery temperature below 30 °C, e.g. by wall mounting.
The voltage of a lithium battery is almost constant throughout the lifetime of the battery  
(approx. 3.65 V). Therefore, it is not possible to determine the remaining capacity of the battery by 
measuring the voltage. However, INFO code 128 indicates that the battery voltage is too low.
The battery cannot and must not be charged and must not be short-circuited. Used batteries must 
be handed in for approved destruction, e.g. to Kamstrup A/S.

Содержание MULTICAL 302

Страница 1: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com Installation and User Guide MULTICAL 302...

Страница 2: ...n with minimum vibration and fixed installation with considerable or high vibration level respectively Electromechanical environment E1 housing light industry The meter s signal cables must be drawn w...

Страница 3: ...ting the function 11 8 Communication 11 8 1 Wired M Bus communication 11 8 2 Wireless M Bus communication radio 11 9 Setup Mode 12 9 1 Changing the installation position 13 9 2 Changing the energy uni...

Страница 4: ...One temperature sensor is mounted in the flow sensor from the factory The other sensor ought to be mounted as direct sensor Alternatively both sensors must be mounted in sensor pockets as symmetrical...

Страница 5: ...meter is configured for static info codes Info code Description Response time 0 No irregularities 1 Supply voltage has been interrupted 4 Temperature sensor T2 outside measuring range 32 secs 8 Tempe...

Страница 6: ...ight inlet MULTICAL 302 requires neither straight inlet nor straight outlet to meet the Mea suring Instruments Directive MID 2004 22 EF and EN 1434 2007 A straight inlet section is only necessary in c...

Страница 7: ...may be turned upwards to max 45 and downwards to max 90 compared to the pipe axis 4 5 4 5 9 0 9 0 4 5 4 5 9 0 9 0 Important The meter is most sensitive to air bubbles in the water when the plastic ca...

Страница 8: ...e upper left corner of the meter display an icon indicates if the meter is positioned in the inlet or outlet pipe It is very important to ensure that the meter is correctly positioned as either inlet...

Страница 9: ...broken In case of strong condensation e g cooling applications wall mounting of the calculator is recommended see paragraph 5 2 page 10 8 3 2 4 5 9 8 3 2 4 5 9 In connection with compact mounting the...

Страница 10: ...flow sensor 6 Battery supply MULTICAL 302 is battery supplied with either 1 or 2 A cell batteries Optimal battery lifetime is obtained by keeping the battery temperature below 30 C e g by wall mountin...

Страница 11: ...2 wire cable of 1 5 m The connection is independent of polarity and the M Bus interface is galvanically separated from the rest of the meter M Bus comes with primary secondary and enhanced secondary a...

Страница 12: ...readings of Setup loop are listed below including index numbers Setup loop Loop_3 Index number in display 1 0 Customer number No 1 3 01 2 0 Customer number No 2 3 02 3 0 Date 3 03 4 0 Hour 3 04 5 0 Ta...

Страница 13: ...ave the setting press the button for two seconds until OK appears in the display Outlet If the meter is set to be placed in the outlet the text Outlet is displayed In order to change the setting press...

Страница 14: ...nd conversely the least significant digit disappears if e g you change from kWh with 1 decimal to kWh without decimals See examples below Example 1 GJ with 2 decimals B 2 This is an example of how the...

Страница 15: ...or registers the amount of district heating water flowing through the heating system in m3 cubic metres The temperature sensors placed in inlet and outlet pipes register the cooling i e the difference...

Страница 16: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com User Guide MULTICAL 302 Kamstrup A S 55121351_D2_GB_04 2015...

Отзывы: