8
Kamstrup A/S • 55122714_A2_GB_04_2021
flowIQ® Gateway
3.2 Electrical data
Fire, explosion and severe burn hazard.
Please follow these guidelines in order to avoid injury to yourself and others:
• If not disposed of properly, the battery may cause fire or chemical burn
• Do NOT recharge, disassemble, crush, expose to water, heat above (100 °C) or
incinerate the battery
• Keep away from children
By connecting to 230 V supply, there is a risk of electric shock.
Battery
3.65 VDC, D-cell lithium
3.65 VDC, 2xA-cell lithium
Battery lifetime
16 years @ tBAT < 30 °C
9 years @ tBAT < 30 °C
Note:
Power supply choices depend on the inserted communication module and lifetime depends
on the chosen communication modules and datagrams.
Mains supply
230 VAC +15/-30 %, 50/60 Hz
24 VAC ±50 %, 50/60 Hz
24 VDC +75/-25 % (24 VDC for High Power SMPS only)
Power consumption
< 1 w
Insulation voltage
3.75 kV
3.3 Mechanical data
flowIQ® Gateway is designed to operate at temperatures of 5 °C…55 °C. Using the device
outside the intended operating temperature range may cause deterioration of battery
life or in worst case operating failure.
Protection class
IP65-rated
Dimensions
166 mm x 102 mm x 47 mm
Wall mount 74 mm x 58 mm
Weight
Approx. 450 g
Operating temperature
5 °C…55 °C non-condensing closed location (indoor installation)
Storage temperature
-25 °C…60 °C
Operating humidity
0 % - 100 % non-condensing
3.4 Material
Top and base
Thermoplastic, PC 10 % GF with TPE (thermoplastic elastomer)
Verification cover
ABS