TECHNICAL DESCRIPTION flowIQ® 3100
58
Kamstrup
A/S • Technical Description •
5512-1242_N
1_GB •
10.2019
If the set up is successful, ‘
PULSE ON
’ is displayed for five seconds and the LED on the unit remains ON for three
seconds
–
shown in the figure below.
It takes only a very short time from setup is started until it is completed.
Having set up the meter, remount the cover on the Pulse Adapter and fasten the three screws.
Display, after set-up
After the
meter display has shown ‘pulse ON’ the water meter is in ‘pulse adapter mode’ and sends optical
pulses to the adapter. This mode has no effect on other meter functions.
Attention:
By laboratory flow tests, using the pulse interface type 66-99-143 the test result can be affected by the pulse
adapter mode.
The ’pulse adapter mode’ can be reset with the software program METERTOOL.
18.5
Pull-up
The acquisition unit must have built-in
’pull
-
up’ –
shown in figure below
–
to ensure correct voltage level of the
pulse. The pulse output is two-wired and must be connected as follows:
Sketch for connection of Pulse Adapter
2