background image

8

.

2.42

  

Katherm QE – 

Tangential fan convection with electric heating element

Ready-to-install convector-based floor trenches

Assembly and installation instructions

7. Dimensions · Connection openings · Heat outputs

Katherm QE

Design

1

 Roll-up grille

2

 Electrical wiring

3

 EC tangential fans

4

 Electric heating element with air 

 baffles

5

 Power control

6

 Safety chain

Room-side connection

Room side

Room side

Top views (views without cover panel)

Top view (without cover panel)

Front view

Side view

Side view
(Cross-section enlarged)

Window side

Window side

1

2

3

4

5

6

Содержание Katherm QE

Страница 1: ...Katherm QE Tangential fan convection with electric heating element Assembly and installation instructions Keep these instructions in a safe place for future use I535 08 18 US I SAP Nr 1280354...

Страница 2: ...one involved with the installation commissioning and use of this product is obliged to pass these instructionsontotradespeople who are involved at the same time or subsequently as well as to end users...

Страница 3: ...e is deemed not to be correct and intended Any damage resulting from this is the sole responsibility of the operator of the unit Correct and proper use is also deemed to include compliance with the in...

Страница 4: ...erate the heater after it malfunctions Disconnect power at service panel and have the heater inspected by a reputable electrician before reusing Do not use outdoors Do not insert or allow foreign obje...

Страница 5: ...the Katherm QE with the convector on the window side Important The height adjustment feet are already fitted to the floor trench They are fixed the wrong way round for transport reasons To install an...

Страница 6: ...here are no sound bridges to the concrete slab especially close to the height adjustment feet appropriate materials have been used to seal all openings and punched openings in the trench heater from t...

Страница 7: ...a tool The grille fixing only needs to be removed on one side at the electrical connection side when wiring Refit the grille fixing once the unit has been wired Installation cover Important Never oper...

Страница 8: ...nection openings Heat outputs Katherm QE Design 1 Roll up grille 2 Electrical wiring 3 EC tangential fans 4 Electric heating element with air baffles 5 Power control 6 Safety chain Room side connectio...

Страница 9: ...the usual measuring and audible range Fan stage Control signal Heat output Electrical power consumption fan Current consump tion Sound pressure level 1 Sound power level V W W A dB A dB A Trench lengt...

Страница 10: ...e unit make sure the power has been turned off at the circuit breaker panel and that the heating element is cool Any other servicing than the mentioned shall be performed by an authorized service repr...

Страница 11: ...s Technical Wiring Regulations Only connect the unit to fixed cables Important note Provide an all pole mains separator in the wiring on site that can be reliably secured to avoid the system being rec...

Страница 12: ...rol or a building management system Group control of several trenches is possible without the need for additional accessories The Katherm QE should be connected or switched in parallel in accordance w...

Страница 13: ...controller Product features flat surface mounted housing colour pure white similar to RAL 9010 operating voltage 24 V AC DC 50 Hz 2 output signals 0 10 V max 5 mA protection class IP 30 control range...

Страница 14: ...Functional description The factory setting activates the electric heating element with a heat output of 20 and at the same time the EC tangential fan with minimum fan revolution at a control voltage o...

Страница 15: ...vin above the room temperature is maintained in accordance with IEC EN 60335 2 30 The triggering of the safety temperature monitor can be signalled via a potential free fault alert contact After recti...

Страница 16: ...M1 Typ146928 room thermostat 1 2 3 4 B1 0 10V GND control signal 0 10VDC 0 2 0V device OFF 2 0 9 5V 0 to 100 heating output N1 R1 HRR V3 US L N C NONC DI1Gnd 24V AI1Gnd AI2 Gnd Gnd Uc 24V Err RPM STB...

Страница 17: ...ired DIP 2 OFF OFF speed increase OFF ON speed increase ON DIP 3 OFF OFF min heating capacity 20 ON min heating capacity 30 DIP 4 OFF N1 HRR V3 US L N C NONC DI1 Gnd 24V AI1 Gnd AI2 Gnd Gnd Uc 24V Err...

Страница 18: ...cription Fits trench length Type number 825 mm 1250 mm 1700 mm Electrical power module X X X 000001264781 Electrical PCB X X X 000001246305 Electrical heating element X 000001264764 X 000001264752 X 0...

Страница 19: ......

Страница 20: ...1628 West 1st Ave Vancouver BC Canada V6J 1G1 T 1 604 789 5779 E info kampmann ca W Kampmann ca Kampmann GmbH Friedrich Ebert Str 128 130 49811 Lingen Ems Germany T 49 591 7108 660 F 49 591 7108 173 E...