4445103340
13
Setting up the water heater
!
1. Place the appliance on a surface that meets the
above requirements.
2. Straighten out all hoses to make sure no kinks
or twists remain.
3. Attach the 12 V DC cable of the water pump
and the water hose to the appliance (see
fig.
4. Attach the gas hose to the appliance (see
5. Attach the other end of the gas hose to the gas
regulator (see fig.
6. Connect the gas regulator to the gas cylinder
following the manufacturers instruction.
7. Check that all connections are tight.
8. Turn on the gas regulator.
!
9. Check all connections for gas leaks:
– Coat all connections, using soapy water.
– If bubbles appear, immediately turn off the
gas regulator and re-tighten the connection
before re-testing.
– If bubbles appear again, do not continue to
use the appliance. Contact an authorized ser-
vice agent.
10. If no leaks are detected, turn the regulator
valve to the “OFF” position.
11. Swing the water outlet tap away from its stor-
age position to the side of the appliance (see
fig.
1.
,
For use of the shower head:
Attach the shower head and hose assembly to
the appliance (see fig.
2.
,
12. Check that the power switch at the rear of the
appliance is in the “OFF” position. Connect
the 12 V DC cable to the appliance and then
connect the 12 V plug to a suitable DC power
source (see fig.
Using the water heater
Requirements for operation
The following equipment is not supplied and must
be provided by the user:
• Butane or propane gas cylinder
• Gas regulator (supply pressure: see chapter
• Gas hose (length: max. 1.5 m)
• 12 V DC supply (e.g. by a vehicle, mains adapter
or battery pack)
• Clean water supply
Gas regulator and gas hose have to be CE
approved and fulfill the national safety require-
ments. In case of questions, contact your retailer or
gas supplier.
Switching on
!
!
I
WARNING! Fire hazard
The location for setting up the water
heater has to meet the following require-
ments:
• outdoors only
• open, well-ventilated area which is
protected from direct winds
• placing surface for the water heater
– out of heat-proof, non-combustible
or non-flammable materials
– standing level on or above the
ground
• solid, stable and flat level
WARNING! Explosion hazard
Do not try to detect gas leaks using a
flame or a pilot light.
WARNING! Fire hazard
• Make sure that all air inlets and
exhausts are kept free from obstruction
and closure.
• The appliance must be operated no
closer than 800 mm to the sides and
800 mm above all combustible sur-
faces, fabrics, flammable materials and
persons.
CAUTION! Health hazard
Do not use water direct from rivers, lakes
or the sea as inlet water.
NOTE
The heater will extinguish if used in a
wind speed above 10 kph.
Содержание Geyser
Страница 101: ...4445103340 101 RU kampaoutdoors com 101 101 103 103 104 105 105 107 107 108 108 108 109 D A I...
Страница 102: ...102 4445103340 8 D...
Страница 103: ...4445103340 103 I 50 C 10 1 3 1 1 2 1 3 1 12 4 1 12 5 1 6 1 1...
Страница 104: ...104 4445103340 Kampa 25 C 75 C 75 C 2 3 1 2 3 4 5 6 7 8 12 9 10 11...
Страница 105: ...4445103340 105 1 2 3 12 3 4 4 5 4 5 6 5 6 7 8 9 10 11 4 1 4 4 2 4 12 12 12 7 6 109 1 5 12...
Страница 107: ...4445103340 107 2 11 3 0 6 5 1 106 2 2 10 3 3 1 2 A 1 2 2 10 3 3 a 7 b 7 4 c 7 d 7 5 12 e 8 6 f 8 7 g 9 8 9 10...
Страница 108: ...108 4445103340 11 kampaoutdoors com store locator M 50 C 50 C 25 C...
Страница 143: ......