background image

3.2  Supplying the Fuel Oil

Beware of fire from oil ignition

be sure to use the correct type of fuel when refueling.

   Filling of gasoline or the like by mistake may cause ignition.

be sure to stop the engine before refueling.

if spilt, wipe such spillage carefully.

Never place oil or other flammable material near engine as this could result in 

ignition.

3.2.1  Filling up the fuel tank

Fill the fuel tank with clean fuel oil not contaminated with dust or water. The tank 

should be filled to approx. 90% of the full capacity. Be careful not to spill it during 

operation.

3.2.2  Bleeding air from the fuel system

unless there is air in the fuel system the fuel cannot be fed to the fuel injection 

pump.

This engine has an automatic bleeding system. Bleed air from the fuel system 

according to the following procedure:

1. Check the oil level in the fuel tank. Add the fuel if insufficient.

2. Open the cock of the fuel tank.

3. Turn the starting switch key to the ON position. The fuel feed pump operates to 

feed the fuel, and when the fuel filter is filled with fuel without any air space or 

bubbles, the engine is ready to be started.

-

-

NOTICE

If draining is neglected, the water remaining in the 

system in cold weather is frozen to damage the cooling 

water system components (radiator, cylinder block, 

cylinder head, etc.)

3. Exterior cleaning, fuel draining, and filling

Clean dirt and oil off from the engine exterior wall.

Thoroughly drain fuel or completely fill the fuel tank for preventing condensation.

Lubricate joints and pivots of the accelerator system.

4. Water-and dust-proofing

Protect the air cleaner, silencer and electrical parts (alternator, starter, switch) 

from water and drain with airtight plastic covers.

Store the engine at a well ventilated place not subject to high moisture or dust.

5. Measure against battery self-discharging

Turn the battery switch off or disconnect the ground lead (-) of the battery.

Recharge the battery monthly to compensate for the self-discharging.

4.6.2 Pre-operation check after long storage

For operation after long storage, make the same preparations as for the initial 

operation. Refer to Section 3-Before Operation.

-

-

Содержание KM2V80

Страница 1: ...KM2V80 V TWI N WATER COOLED DIESEL ENGINE...

Страница 2: ...E OPERATION 3 1 Preparation of Fuel Oil Lube Oil Cooling Water 3 2 Supplying the Fuel Oil 3 3 Supplying the Lube Oil 3 4 Supplying the Cooling Water 3 5 Cranking No load 3 6 Checking the Lube oil and...

Страница 3: ...3 1 1 3 1 1 SYMPTOM Ref Section PROBABLE CAUSEACTION Self starter not running hand turn possible hand turn not possible Low battery voltage Poor contact of cable terminals Faulty starter switch Fault...

Страница 4: ...an flywheel or PTO shaft Never operate the engine without covers on the rotating parts Check before starting the engine to see that any tools or cloths used in the maintenance remains around the engin...

Страница 5: ...void scalding Wait until the temperature goes down before draining the coolant Hot water may splash to burn you Beware of dirt from air blowing Wear protective equipment such as goggles to protect you...

Страница 6: ...h to cause scalding Cooling water contaminated with rust or water scale reduces the cooling effect Even when antifreeze or anti corrosive agent is mixed the cooling water gets contaminated due to dete...

Страница 7: ...instruments alarms etc are provided to meet various operating conditions Since installation and fitting of the engine require special knowledge and skill always consult with your dealer or KAMA distri...

Страница 8: ...3 3 Check every 200 hours of operation 1 Replacing lube oil and lube oil filter 2nd time and after Replace the lube oil every 200 hours of operation from the second time and on Replace the lube oil fi...

Страница 9: ...cal PTO shaft opposite to flywheel Counterclockwise as viewed from opposite of the flywheel 3 Cleaning the air cleaner Beware of dirt from air blowing Wear protective equipment such as goggles to prot...

Страница 10: ...ated during operation or charging may be ignited to start a fire Beware of battery electrolyte Be careful so as not to bring your skin or eye in contact with the battery electrolyte which is a strong...

Страница 11: ...d to the sub tank are cooled down to water again When the load is reduced and the cooling water temperature drops the radiator internal pressure becomes negative and vacuum valve on the radiator cap o...

Страница 12: ...low plug is energized while the starting switch is at the HEAT position When using the glow plug keep the starting switch at HEAT for approx 15 seconds and then turn it to the START to start the engin...

Страница 13: ...Control lever Speed limiting bolt Check Replace Consult KAMA dealer or distributor Initial Later 50h 200h 400h 1000h 2000h Check item System Daily checks Periodic check intervals Fuel tank oil level...

Страница 14: ...in the specified order For maintenance requiring removal of parts consult with your dealer or KAMA distributor The table below lists the standard tightening torques Tightening torques listed below are...

Страница 15: ...by the manufacturer NOTICE NOTICE 5 1 Checking Periodic check The engine performance may deteriorate to the operation conditions and period of operation Negligence of deteriorated functions and perfor...

Страница 16: ...el feed pump operates to feed the fuel and when the fuel filter is filled with fuel without any air space or bubbles the engine is ready to be started NOTICE If draining is neglected the water remaini...

Страница 17: ...ake the following care 4 6 1 Inspection and maintenance during long term storage 1 Periodic check If the next periodic check is drawing near carry out the inspection before storage 2 Draining of cooli...

Страница 18: ...ever switch off the battery or make a spark on the battery cable during operation An abnormal surge can cause malfunctioning of the electrical system 4 5 Stopping the engine To stop the engine take th...

Страница 19: ...speed Adjust the engine speed by operating the accelerator lever control lever Move the lever upward to raise the speed and downward to reduce the speed Slowly operate the lever Do not try abrupt acce...

Страница 20: ...3 For addition of cooling water refer to section 3 4 Before in operation STOP HEAT HEAT OFF ON START Starting switch Release the key after starting Limit the activation of the glow plug within 20 sec...

Страница 21: ...dy during operation or immediately after stopping Never touch these parts with your body or clothing Otherwise scalding will result 4 OPERATION WARNING CAUTION WARNING 4 2 Starting 4 2 1 Normal starti...

Страница 22: ...en the engine is hot is dangerous And the water volume is expanded due to the heat 1 Check the cooling water level in the sub tank If the water level is close to the lower limit open the sub tank cap...