background image

 

 
 

 

21

4.3

 

Appliances with radio remote control 

 

Take the battery-protection strip out of the manual transmitter and check 

that the battery is still correctly positioned between the two contacts. 
Plug into the electric socket and turn on the gas tap. 

 

4.3.1

 

Lighting the burners 

When the Big flame (Figure 14 no. 1) and the “Off” knob (no. 3) are 

pushed in simultaneously (two-knob ignition!!), after a few seconds the 

ignition will automatically start sparking. When the pipe and the gas 

control unit are filled with gas, a pilot light will appear and the sparking 

will stop. If the sparking does NOT 

stop, there can only be two reasons for 

this: the gas supply is still closed off 
(no pilot light can be seen); in this 

case turn on the gas tap - or the plug 

is not pushed into the electric socket 
correctly (there is a pilot light, but the 

ignition keeps on sparking), then the 

plug has to be turned round in the 

electric socket (NL) or the L and N 
wires need to be swapped over in the 

black receiver box (BE). When the pilot 

light is burning, the main burners will 
start with a large flame and are then 

continuously adjustable between maximum and minimum. You can adjust 

the burners higher and lower with no. 1 and no. 2. 
 

Resetten the appliance 

If still no flame is detected after 30 seconds of 

sparking, the automated burner unit safety-lock 
will be activated. You can reset the automatic 

burner unit by means of the remote control and/or 

a reset knob on the automatic burner unit itself. 
(This procedure may have to be repeated several 

times when the appliance is first used or if it has 

been out of use for an extended period). 
 

I   On the remote control you then press in the 

“small flame” and “X” simultaneously (1) and 

then immediately press “X” (2) again. (see 
Figure 15). 

Figuur 15 resetten 

Figure 14 resetting 

 

 
 

 

22

 

II  If the automatic burner unit (Figure 16) is accessible, this can be 

reset by pressing in a reset knob (3). You can see that this is locked 

by the red lamp (3).  

 

After the reset cycle, lasting about 10 
seconds, you can re-start by 

simultaneously pressing the ON and OFF 

knob. 
 

 

 

4.3.2

 

Extinguishing the burners 

To completely extinguish the fire, press the OFF knob (Figure 14 no. 3) 

on the transmitter, and the main burners as well as the pilot light will go 

out completely. 
If the electricity supply is interrupted, the fire will also go out. 

 

If you are going to be away for an extended period, it is advisable to turn 
off the gas supply to the appliance. 

 

Figure 16 resetting 

Содержание TWIN 38x15

Страница 1: ...NTROL UNIT 7 2 6 ASSEMBLY OF THE RADIOGRAFIC GAS CONTROL UNIT 8 2 7 POSITIONING OF THE CHIPS AND LOGS 11 2 8 EXTRA ACCESOIRES 14 2 8 1 OPTIONAL SET OF LOGS 14 2 8 2 THE FLOORBURNER 14 3 TECHNICAL DATA 16 3 1 3 1 TWIN 38 15 16 3 2 3 2 TWIN 50 15 16 3 3 3 3 TWIN 80 15 16 4 OPERATING INSTRUCTIONS 17 4 1 MANUAL CONTROLLED APPLIANCES 17 4 1 1 LIGHTING THE BURNERS 17 4 1 2 EXTINGUISHING THE BURNERS 18 4...

Страница 2: ...RICAL CONNECTION WITH FAN 31 ANNEX 3 GRAFIC FOR CALCULATION FLUE DUCT 32 4 Inleiding The open gas log fire from the TWIN series of the brand KAL FIRE you have purchased is a product of which you will enjoy great pleasure in heating year after year We recommend checking the appliance at delivery for possible transport damage Carefully read the accompanying instructions before installing or taking t...

Страница 3: ...least 15 cm per kW maximum output Construction of a controlled flue gas regulator 6 Flue gasses have to be evacuated by means of a fan designed for flue gasses The appliance has to be equipped with a flow protection thermal shut off safety or oxistop A fan suitable for evacuation of flue gasses has to be used Kal Fire recommends the EXHAUSTO RSVG fans Inatherm 1 2 General requirements A The flue m...

Страница 4: ...he ultrasonic gas control unit The appliance is standardly delivered connected to the gas control unit and has to be connected to the gas tap not included as following Connect the gas supply 12 mm to the gas control unit 12 mm clamp Test leak tightness of the system by means of soapsuds or leakage testing spray Check the protection system by activating the security the appliance should go out 8 As...

Страница 5: ...connect an EXHAUSTO RSVG fan For this purpose the electrical layout has to be changed to the the plan in annex 2 An extra wire is include for this purpose and has to be connected as below Step 1 Remove plug 1 Step 2 Insert the delivered plug onto the cable tree Step 3 Connect the other four cables to the EFC 21 EFC 25 10 ATTENTION This receiver has tob e mounted outside of the burner s radiation a...

Страница 6: ...n place it is best to position the rearmost log first and also the two logs on either side The chips can then be laid on the logs There will then be plenty of air under these logs which will produce a better glow Tip 3 You may partly cover the pilot light cap but you must be able to see that the pilot light is burning at all times This will produce a more realistic effect Caution The chips must no...

Страница 7: ...ra accesoires 2 8 1 Optional set of logs For the TWIN 5015 extra accessoires can be ordered It is possible to order an optional set of logs This is the optional set of logs 2 8 2 The floorburner It is possible to built the gas log fire in a sunken casing An advantage of this is that it is included with a controlled air supply and a burner plate as a cover 1 3 2 4 5 ...

Страница 8: ... AT CH GB IT Propaan Type B11 B21 B11 B21 B11 B21 B11 B21 B11 B21 Gas P G20 20 mbar G20 20 mbar G25 25 mbar G25 25 mbar G25 20 mbar G20 20 mbar G30 37 mbar Gascat I2L I2E I2ELL I2H I3P Input 17 45 kW 18 38 kW 15 53 kW 15 17 kW Max min 2 14 0 73 m3 h 1 94 0 83 m3 h 1 92 0 78 m3 h 0 61 0 23 m3 h Branderdruk 23 8 mbar 18 8 mbar 19 0 mbar 36 7 mbar 18 38 kW 1 94 0 75 m3 h 18 8 mbar Model NL BE FR DE A...

Страница 9: ... in until the pilot light is burning steadily This can take longer straight after mounting because the gas pipe still has to fill with gas When the pilot light is burning keep the knob 1 pressed in for approximately another 20 seconds otherwise repeat the above operation 1 2 Figure 11 Manually controlled appliance 18 Now release the knob 1 If the pilot light does not keep burning wait for 3 minute...

Страница 10: ...e knob 3 If the pilot light does not keep burning wait for 3 minutes and then repeat the above steps Now turn the knob 3 fully in the opposite direction as far as the position with the big flame You can now adjust the height of the flames with the remote control Figure 13 For higher flames press in the top knob 6 and the left hand knob 8 simultaneously For lower flames press in the bottom knob 7 T...

Страница 11: ...inimum You can adjust the burners higher and lower with no 1 and no 2 Resetten the appliance If still no flame is detected after 30 seconds of sparking the automated burner unit safety lock will be activated You can reset the automatic burner unit by means of the remote control and or a reset knob on the automatic burner unit itself This procedure may have to be repeated several times when the app...

Страница 12: ...ng blown away This could be because the chips are lying in front of the pilot light Reposition them and try again Check whether the distance between ionization pen and thermocouple is not too great to spark across If necessary bend closer Nee No Ja Yes No Yes No Contact your dealer Check whether the gas tap is open or that there is a blockage in the gas supply No No Yes Yes Does the microswitch sh...

Страница 13: ... on Ignition sparks and pilot light comes on but does it also stay on Burner bed comes on The TWIN burns very blue It needs 30 minutes in order to heat up completely Please contact your dealer about other problems Does pilot light go out directly Is a red lamp alight reset knob on the gas control unit or does the fire not react Can you hear a click when you press the remote control Check that igni...

Страница 14: ... starting on the date of purchase which must be clearly and distinctly stated on the sales invoice The attached warranty registration card should be carefully completed and returned to Kal Fire B V 3 The warranty does not cover the ceramic glass or external physical and chemical effects during transit storage or assembly 4 If a problem should however occur within the warranty period due to a manuf...

Страница 15: ...ed or different ones are placed on the burner bed 7 If this warranty certificate together with the original dated proof of purchase cannot be produced likewise if it appears that the details in this proof of purchase have been manipulated date deleted made illegible changed etc 30 Annex 1 Outlet area s Schuin dak Dakhelling 23 Plat dak Schuin dak Dakhelling 23 I I III III 0 5 m 0 5 m 0 8 m I Flat ...

Страница 16: ...e buttons High en X 2 1 TTB 230V Inatherm Chimney Fan Fan dP Pressure differential NO NC C L Nre PE Inatherm EFC21 L N PE 8 9 10 11 12 13 14 15 POWER 2 1 GNYE START IN AIR INLET RELEASE OUT STEP 2 OUT 1 2 3 4 5 P D S F A N 6 7 S M G X1 1 11 X1 2 1 8 9 11 4 13 Earth to gasregulator 2 1 GNYE L N GND Power Earthing Phase terminal Y1 Y2 32 Annex 3 Grafic for calculation flue duct 0 2 0 3 0 4 0 5 0 6 0...

Отзывы: