2. Safety
6
2.4.2
Installation of the Heat Pure 90 corner in combination with
combustible materials (e.g. a wooden wall)
When installing the Heat Pure 90 corner pay attention to the distance to
combustible building materials:
Image: cross-section of a corner Heat Pure 90 corner
Combustible materials must be shielded by insulation material with a
minimum thickness of 10 cm.
* The floor the Heat Pure 90 corner is placed on must be made
of non-combustible materials. The (combustible) floor in front
of the door opening must be protected to a distance of at least
50 cm in front of the appliance (side/sides with a glass door).