6. Maintenance
48
6
Maintenance
6.1
Keeping clean panes
To keep the panes clean:
•
Only burn dry wood (with a moisture level of approximately 15% and
stored dry and chopped for 2 years).
•
Open the air supply completely (100%).
•
Open the damper completely (if present).
•
Ensure the flue has a minimum draught of 12 Pa.
COMMENTS:
•
The risk of soot building up on the glass panel during combustion
is higher with a rear panel of steel slats than with a vermiculite
rear panel.
•
Due to the smaller surface area of vermiculite in the two-sided
(tunnel) Heat Pure 80 and Heat Pure 105, the risk of soot build-
up on the glass panel is higher.