3. Mounting and installation
30
This may have a number of causes:
-
Insufficient pull in the chimney duct
-
The air flow patterns in the room where the 3-sided fireplace has
been installed
-
Too low ignition temperature.
Heat Pure 80 tunnel and Heat Pure 105 tunnel
The Heat Pure 80 and Heat Pure 105 tunnel
has several removable baffle plates. These
baffle plates are situated above the smoke
hood just below the heat exchanger. The
baffle plate ensures an optimal combustion.
In the following situations, it may be
necessary to remove the baffle plate or
decrease it’s the size.
•
Smoke return when the Heat Pure starts
•
Condensation in the flue duct
If necessary, you can adjust the baffle plate
as follows:
1.
Remove all baffle plates and see if this
solves the problem. If the problem still
occurs, then something else is the cause.
If removing the plate solves the problem,
proceed with the next step.
2.
Use a saw or knife to cut away a strip of 1 cm wide at the front of
the baffle plate. Do not remove too much. The baffle plate must still
be able to rest on the bracket. A maximum of 6 cm can be removed
from the baffle plate.
3.
In certain situations it may be necessary to remove the baffle plate
entirely.
The Heat Pure 105 tunnel is not suitable to be used as an
open fire place.
Baffle plates
Содержание Heat Pure Series 105T
Страница 40: ...5 Lighting the fireplace 37 Figure 2 end of the key Operating the door Operating the air regulation...
Страница 65: ...APPENDIX B Dimension diagrams B6 Heat Pure 90 3 sided Front view side view...
Страница 66: ...APPENDIX B Dimension diagrams B7 Heat Pure 80 tunnel Front view Side view...
Страница 71: ......
Страница 72: ......