3. Mounting and installation
28
3.8.1 Practical examples of connection: combustion air and convection
Situation 1 - Recommended situation
The combustion air is connected directly to
the Heat Pure from outside. The outside air is
not in contact with the room the appliance is
installed in or with the chimneybreast. The
convection system is also connected directly
to the Heat Pure. There are no open
connections between the interior of the
chimneybreast and the room in which the
appliance is installed.
Situation 2:
The combustion air is connected directly to
the Heat Pure from outside. The outside air is
not in contact with the room the appliance is
installed in or with the chimneybreast. The
convection system is only in contact to the
room in which the appliance is installed.
Situation 3:
The combustion air cannot be connected
directly to the Heat Pure; this air must be
taken from the room the appliance is installed
in. This mainly occurs in an existing situation,
in which the combustion air can only be taken
from the room the appliance is in.
The convection system must then be
physically separated from the combustion air;
connect the lower and upper convection
gratings directly to the Heat Pure. The
combustion air reaches the Heat Pure through
extra openings in the chimneybreast. See
Technical Specifications (table 4) for the
through put of these openings.
The convection connections at the top of the appliance must be
connected at all times.
Содержание Heat Pure Series 105T
Страница 40: ...5 Lighting the fireplace 37 Figure 2 end of the key Operating the door Operating the air regulation...
Страница 65: ...APPENDIX B Dimension diagrams B6 Heat Pure 90 3 sided Front view side view...
Страница 66: ...APPENDIX B Dimension diagrams B7 Heat Pure 80 tunnel Front view Side view...
Страница 71: ......
Страница 72: ......